CVE-2023-1698

criticalPriorität · verfolgen · 39EPSS 0.819 · 100. PerzentilExploit · PoCDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
4 exploits · PoC
Likely / severe?
81.9% (100th) EPSS
CVSS 9.8 · critical
Is it mine?
48 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · endress_hauser_psirt

EPSS · bewertet 2026-10-27

In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • Behobenwago_psirt

    Wago recommends all affected users to update to the firmware version listed below: | Article No° | Product Name | Fixed Version | |----------------------|------------------------------|----------------------------------| | 751-9301 | Compact Controller CC100 | FW24 | | 752-8303/8000-002 | Edge Controller | FW22 | | 752-8303/8000-002 | Edge Controller | FW24 | | 750-81xx/xxx-xxx | PFC100 | FW22 SP1 | | 750-82xx/xxx-xxx | PFC200 | FW22 SP1 l | | 750-821x/xxx-xxx | PFC200 | FW24 | | 762-5xxx | Touch Panel 600 Advanced Line| FW22 SP1 | | 762-5xxx | Touch Panel 600 Advanced Line| FW24 | | 762-6xxx | Touch Panel 600 Marine Line | FW22 SP1 | | 762-6xxx | Touch Panel 600 Marine Line | FW24 | | 762-4xxx | Touch Panel 600 Standard Line| FW22 SP1 | | 762-4xxx | Touch Panel 600 Standard Line| FW24 |

  • Behobenendress_hauser_psirt

    Endress+Hauser provides updated firmware versions for the related components from WAGO which fixes the vulnerability. Endress+Hauser strongly recommends customers to update to the new fixed version. For support, please contact your local service center.

  • Mitigationwago_psirt

    As general security measures strongly WAGO recommends: Use general security best practices to protect systems from local and network attacks. Do not allow direct access to the device from untrusted networks. Update to the latest firmware according to the table in chapter solutions. Industrial control systems (ICS) should not be directly accessible from the Internet, but should be protected by consistently applying the defense-in-depth strategy. The BSI provides general information on securing ICS in the ICS Compendium (https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/ICS/ICS-Security_compendium.pdf).

  • Mitigationendress_hauser_psirt

    If an immediate firmware update is not possible, the only way to prevent an attack is to prevent the access of the Web Based Management tool from the internet. This can be achieved by using a network element, such as a router, which hides and secures the components from the internet.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · info@cert.vde.comAusnutzbarkeit 3.9 · Auswirkung 5.9
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · WAGO PSIRT DE
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · Endress+Hauser PSIRT DE
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Hsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: yes · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

Exploits (4)

Öffentlicher Proof-of-Concept- und Exploit-Code.

06

betroffene Produkte (48)

Betroffene Produkte und Versionsbereiche.

07

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • VDE-2023-007WAGO: Unauthenticated command execution via Web-based-management UPDATE A2023-05-15csaf · wago_psirtDE

    The 'legal information' plugin of web-based-management contained a vulnerability which allowed execution of arbitrary commands with privileges of www user. UPDATE A 15.06.2023 : Removed PFC100 with FW23 as affected product and from solution PFC200 with FW23 is only affected on 750-821x/xxx-xxx Renamed "FW22 Patch 1" to "FW22 SP1" to match the versions of the download portal

  • VDE-2024-054Endress+Hauser: Netilion Network Insights is affected by multiple vulnerabilities2024-10-21csaf · endress_hauser_psirtDE

    Several vulnerabilities have been identified in the web-based management of WAGO devices utilized in Endress+Hauser IoT solutions. WAGO has provided fixes for these vulnerabilities, which have been integrated into the solutions by Endress+Hauser. Additionally, a guideline on secure operation of these solutions has been made available.

08

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

09

quellen

Welche Quellen diesen Datensatz belegen und wann.

10

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan