CVE-2022-45092
highPriorität · beachten · 46EPSS 0.314 · 98. PerzentilDEEURUUSEPSS · bewertet 2026-10-26
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSINEC INSsiemens_psirt
Update to V1.0 SP2 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815432/ - BehobenSINEC INScisa_csaf_ot
Update to V1.0 SP2 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815432/
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 8.1–9.9
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (7)
Betroffene Produkte und Versionsbereiche.
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-332410SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 12023-01-10csaf · siemens_psirtDE
Siemens has released a new version for SINEC INS that fixes multiple vulnerabilities that could allow an attacker to read and write arbitrary files from the file system of the affected component and to ultimately execute arbitrary code on the device. In addition, this version also contains fixes for multiple vulnerabilities in underlying third party components. Siemens has released an update for SINEC INS and recommends to update to the latest version.
- ICSA-23-017-03Siemens SINEC INS2023-01-10icsa · cisa_csaf_otUS
Siemens has released a new version for SINEC INS that fixes multiple vulnerabilities that could allow an attacker to read and write arbitrary files from the file system of the affected component and to ultimately execute arbitrary code on the device. In addition, this version also contains fixes for multiple vulnerabilities in underlying third party components. Siemens has released an update for SINEC INS and recommends to update to the latest version.