CVE-2022-44725
highPriorität · verfolgen · 31EPSS 0.002 · 8. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
OPC Foundation Local Discovery Server (LDS) through 1.04.403.478 uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS (running as a high-privilege user).
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenTeleControl Server Basic V3siemens_psirt
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - BehobenSIMATIC NET PC Software V16siemens_psirt
Update to V16 Update 8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974091/ - BehobenSIMATIC NET PC Software V17siemens_psirt
Update to V17 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820674/ - BehobenSIMATIC NET PC Software V18siemens_psirt
Update to V18 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826242/ - BehobenSIMATIC Process Historian 2022 OPC UA Serversiemens_psirt
In the context of SIMATIC PCS neo, update to SIMATIC PCS neo V4.1 or later version
- BehobenSIMATIC WinCCsiemens_psirt
Update to V8.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816599/ - BehobenSIMATIC WinCC Runtime Professionalsiemens_psirt
Update to V18 Update 2 or later version
- BehobenSIMATIC WinCC Unified PC Runtime V18siemens_psirt
Update to V18.0 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109807123/ - BehobenSIMATIC NET PC Software V16cisa_csaf_ot
Update to V16 Update 8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974091/ - BehobenSIMATIC NET PC Software V17cisa_csaf_ot
Update to V17 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808270/ - BehobenSIMATIC NET PC Software V18cisa_csaf_ot
Update to V18 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826242/ - BehobenSIMATIC Process Historian 2022 OPC UA Servercisa_csaf_ot
In the context of SIMATIC PCS neo, update to SIMATIC PCS neo V4.1 or later version
- BehobenSIMATIC WinCCcisa_csaf_ot
Update to V8.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816599/ - BehobenSIMATIC WinCC Runtime Professionalcisa_csaf_ot
Update to V18 Update 2 or later version
- BehobenSIMATIC WinCC Unified PC Runtime V18cisa_csaf_ot
Update to V18.0 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109807123/ - BehobenTeleControl Server Basic V3cisa_csaf_ot
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - BehobenSIMATIC NET PC Software V17cisa_csaf_ot
Update to V17 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820674/ - MitigationOpenPCS 7 V9.1siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V14siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V15siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V16siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V17siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V18siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC Process Historian 2020 OPC UA Serversiemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC Process Historian 2022 OPC UA Serversiemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC WinCCsiemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC WinCC Runtime Professionalsiemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC WinCC Unified PC Runtime V18siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationTeleControl Server Basic V3siemens_psirt
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationOpenPCS 7 V9.1cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC NET PC Software V14cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC NET PC Software V15cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC NET PC Software V16cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC NET PC Software V17cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC NET PC Software V18cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC Process Historian 2020 OPC UA Servercisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC Process Historian 2022 OPC UA Servercisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC WinCCcisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC WinCC Runtime Professionalcisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationSIMATIC WinCC Unified PC Runtime V18cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationTeleControl Server Basic V3cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to V1.04.405 or later if possible
- MitigationOpenPCS 7 V9.1cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V14cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V15cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V16cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V17cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC NET PC Software V18cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC Process Historian 2020 OPC UA Servercisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC Process Historian 2022 OPC UA Servercisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC WinCCcisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC WinCC Runtime Professionalcisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationSIMATIC WinCC Unified PC Runtime V18cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- MitigationTeleControl Server Basic V3cisa_csaf_ot
Update the underlying OPC Foundation Unified Architecture Local Discovery Server (UA-LDS) to [V1.04.405](https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/) or later if possible
- Kein Fix geplantOpenPCS 7 V9.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V14siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V15siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC Process Historian 2020 OPC UA Serversiemens_psirt
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V9.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V14cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V15cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC Process Historian 2020 OPC UA Servercisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (53)
Betroffene Produkte und Versionsbereiche.
Advisories (4)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-556635SSA-556635: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.02024-04-09csaf · siemens_psirtDE
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.
- SSA-691715SSA-691715: Vulnerability in OPC Foundation Local Discovery Server Affecting Siemens Products2023-04-11csaf · siemens_psirtDE
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-23-103-03Siemens in OPC Foundation Local Discovery Server2023-04-11icsa · cisa_csaf_otUS
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-24-102-08Siemens OPC Foundation Local Discovery Server Affecting Siemens Products2023-04-11icsa · cisa_csaf_otUS
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
auch bekannt als (5)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (7)
Externe Belege — Patches, Meldungen, Analysen.
- https://cxsecurity.com/cveshow/CVE-2022-44725/cnnvd
- https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2022-44725.pdfcnnvd
- https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/cnnvd
- https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2022-44725.pdfenisa_euvd
- https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/enisa_euvd
- https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2022-44725.pdfPatchVendor Advisorynvd
- https://opcfoundation.org/developer-tools/samples-and-tools-unified-architecture/local-discovery-server-lds/PatchVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan