CVE-2022-44457

criticalPriorität · verfolgen · 39OT-Risiko · erhöhtEPSS 0.008 · 55. PerzentilDEEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.76% (55th) EPSS
CVSS 9.8 · critical
Is it mine?
31 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · cisa_csaf_ot · siemens_psirt

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.4–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 5.9
v3.17.4highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HsecondaryAusnutzbarkeit 3.9 · Auswirkung 5.9
v3.17.4highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: yes · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (31)

Betroffene Produkte und Versionsbereiche.

20 von 31 angezeigt
06

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-638652SSA-638652: Authentication Bypass Vulnerability in Mendix SAML Module2022-09-13csaf · siemens_psirtDE

    The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions are introduced in two release steps: - The first fix versions address CVE-2022-37011. It removes the vulnerability, except when the not recommended, non default configuration option 'Allow Idp Initiated Authentication' is enabled. - The second fix versions address CVE-2022-44457, which removes the issue for the non default configuration as well.

  • ICSA-22-258-04Siemens Mendix SAML Module2022-09-13icsa · cisa_csaf_otUS

    The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions are introduced in two release steps: - The first fix versions address CVE-2022-37011. It removes the vulnerability, except when the not recommended, non default configuration option 'Allow Idp Initiated Authentication' is enabled. - The second fix versions address CVE-2022-44457, which removes the issue for the non default configuration as well.

07

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2022-11-08geändert 2026-06-17
10

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan