The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information (ePHI), protected health information (PHI) or personally identifiable information (PII) is stored in the pump.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenBodyGuard Pumpscisa_csaf_ot
For additional information, users should see BDs security bulletin.
https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability - BehobenCME BodyGuard 323cisa_csaf_ot
For additional information, users should see BDs security bulletin.
https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability - BehobenCME BodyGuard 323 Color Visioncisa_csaf_ot
For additional information, users should see BDs security bulletin.
https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability - BehobenCME BodyGuard Twinscisa_csaf_ot
For additional information, users should see BDs security bulletin.
https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (21)
Betroffene Produkte und Versionsbereiche.
- Becton, Dickinson and Company (BD) BodyGuard™ Pump≤ CME BodyGuard™ 323 Color Vision (2nd Edition)enisa_euvdEU
- Becton, Dickinson and Company (BD) BodyGuard™ Pump≤ CME BodyGuard™ 323 Color Vision (3rd Edition)enisa_euvdEU
- bd bodyguard 121 twins firmwarealle VersionennvdUScpe:2.3:o:bd:bodyguard_121_twins_firmware:*:*:*:*:*:*:*:*
- bd bodyguard 323 colorvision firmwarealle VersionennvdUScpe:2.3:o:bd:bodyguard_323_colorvision_firmware:*:*:*:*:*:*:*:*
- bd bodyguard 999-603 firmwarealle VersionennvdUScpe:2.3:o:bd:bodyguard_999-603_firmware:*:*:*:*:*:*:*:*
- bd bodyguard duo 999-903 firmwarealle VersionennvdUScpe:2.3:o:bd:bodyguard_duo_999-903_firmware:*:*:*:*:*:*:*:*
- bd bodyguard epidural 999-683 firmwarealle VersionennvdUScpe:2.3:o:bd:bodyguard_epidural_999-683_firmware:*:*:*:*:*:*:*:*
- bd bodyguard pain manager 999-803 firmwarealle VersionennvdUScpe:2.3:o:bd:bodyguard_pain_manager_999-803_firmware:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSMA-22-335-01BD BodyGuard Pumps2022-12-01icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could allow an attacker to change configuration settings or disable the pump.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
- https://cxsecurity.com/cveshow/CVE-2022-43557/cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.6280cnnvd
- https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerabilitycnnvd
- https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerabilityenisa_euvd
- https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerabilityMitigationVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan