CVE-2022-4304
mediumPriorität · verfolgen · 42EPSS 0.235 · 98. PerzentilExploit · PoCDEEUNLRUUSEPSS · bewertet 2026-10-23
A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
Update to V8.10.0.9 or later version The update is available upon request from customer support
- BehobenSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
Update to V8.10.0.9 or later version The update is available upon request from customer support
- BehobenSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
Update to V8.10.0.9 or later version The update is available upon request from customer support
- BehobenSIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)siemens_psirt
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109822278/ - BehobenSIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)siemens_psirt
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109822278/ - BehobenSIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)siemens_psirt
Update to V2.9.7 or later version
- BehobenSIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)siemens_psirt
Update to V2.9.7 or later version
- BehobenSIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47353723/ - BehobenSIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354354/ - BehobenSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)siemens_psirt
Update to V21.9.7 or later version
- BehobenSIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354502/ - BehobenSIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354578/ - BehobenSIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/62612377/ - BehobenSIMATIC PDM V9.2siemens_psirt
Update to V9.2 SP2 Upd1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - BehobenSIMATIC Process Historian 2022 OPC UA Serversiemens_psirt
Update to V2022 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825230/ - BehobenSIMATIC S7-1200 CPU family (incl. SIPLUS variants)siemens_psirt
Update to V4.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109976907/ - BehobenSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 Software Controller V2siemens_psirt
Update to V21.9.7 or later version
- BehobenSIMATIC S7-1500 Software Controller V3siemens_psirt
Update to V30.1.0 or later version
- BehobenSIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)siemens_psirt
Update to V3.3.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/51466769/ - BehobenSIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40360647/ - BehobenSIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40944925/ - BehobenSIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/85049260/ - BehobenSIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40362228/ - BehobenSIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40945128/ - BehobenSIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/85059804/ - BehobenSIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/85063017/ - BehobenSIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/44442927/ - BehobenSIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/44443101/ - BehobenSIMATIC S7-PLCSIM Advancedsiemens_psirt
Update to V6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821388 - BehobenSIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47353723/ - BehobenSIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354354/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)siemens_psirt
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)siemens_psirt
Update to V3.3.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/51466769/ - BehobenSIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40360647/ - BehobenSIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40944925/ - BehobenSIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40362228/ - BehobenSIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)siemens_psirt
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40945128/ - BehobenSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenTIM 1531 IRC (6GK7543-1MX00-0XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenTeleControl Server Basic V3siemens_psirt
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - BehobenSIMATIC MV540 H (6GF3540-0GE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV540 S (6GF3540-0CD10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV550 H (6GF3550-0GE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV550 S (6GF3550-0CD10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV560 U (6GF3560-0LE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV560 X (6GF3560-0HE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208 (6GK5208-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208EEC (6GK5208-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G (6GK5208-0GA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216 (6GK5216-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C (6GK5216-4BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216EEC (6GK5216-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224 (6GK5224-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204 (6GK5204-0BA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208 (6GK5208-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208EEC (6GK5208-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216 (6GK5216-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216EEC (6GK5216-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - BehobenSCALANCE XM408-4C (6GK5408-4GP00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM408-8C (6GK5408-8GS00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM416-4C (6GK5416-4GS00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (6GK5528-0AA00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (6GK5552-0AA00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSINEC NMSsiemens_psirt
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - Behobenphoenix_contact_psirt
The vulnerabilities are fixed in firmware versions 8.9.1 and 10.2.0. We strongly recommend all affected FL MGUARD users to upgrade to this or a later version.
- BehobenSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
Update to V8.10.0.9 or later version The update is available upon request from customer support
- BehobenSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
Update to V8.10.0.9 or later version The update is available upon request from customer support
- BehobenSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
Update to V8.10.0.9 or later version The update is available upon request from customer support
- BehobenRTU500 series CMU Firmwarecisa_csaf_ot
RTU500 series CMU Firmware version 12.0.1 - 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)
- BehobenSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - BehobenSIMATIC MV540 H (6GF3540-0GE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV540 S (6GF3540-0CD10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV550 H (6GF3550-0GE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV550 S (6GF3550-0CD10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV560 U (6GF3560-0LE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC MV560 X (6GF3560-0HE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - BehobenSIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)cisa_csaf_ot
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109822278/ - BehobenSIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)cisa_csaf_ot
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109822278/ - BehobenSIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
- BehobenSIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
- BehobenSIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47353723/ - BehobenSIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354354/ - BehobenSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)cisa_csaf_ot
Update to V21.9.7 or later version
- BehobenSIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354502/ - BehobenSIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354578/ - BehobenSIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/62612377/ - BehobenSIMATIC PDM V9.2cisa_csaf_ot
Update to V9.2 SP2 Upd1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - BehobenSIMATIC Process Historian 2022 OPC UA Servercisa_csaf_ot
Update to V2022 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825230/ - BehobenSIMATIC S7-1200 CPU family (incl. SIPLUS variants)cisa_csaf_ot
Update to V4.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109976907/ - BehobenSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 Software Controller V2cisa_csaf_ot
Update to V21.9.7 or later version
- BehobenSIMATIC S7-1500 Software Controller V3cisa_csaf_ot
Update to V30.1.0 or later version
- BehobenSIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)cisa_csaf_ot
Update to V3.3.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/51466769/ - BehobenSIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40360647/ - BehobenSIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40944925/ - BehobenSIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/85049260/ - BehobenSIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40362228/ - BehobenSIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40945128/ - BehobenSIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/85059804/ - BehobenSIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/85063017/ - BehobenSIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/44442927/ - BehobenSIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/44443101/ - BehobenSIMATIC S7-PLCSIM Advancedcisa_csaf_ot
Update to V6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821388 - BehobenSIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47353723/ - BehobenSIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/47354354/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)cisa_csaf_ot
Update to V3.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)cisa_csaf_ot
Update to V3.3.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/51466769/ - BehobenSIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40360647/ - BehobenSIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40944925/ - BehobenSIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40362228/ - BehobenSIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)cisa_csaf_ot
Update to V3.2.19 or later version
https://support.industry.siemens.com/cs/ww/en/view/40945128/ - BehobenLumada APM Edgecisa_csaf_ot
Hitachi Energy has fixed the vulnerabilities for Lumada APM in version 6.5.0.2 and later and recommends users update their systems to the appropriate version. Lumada APM Edge versions 4.0 and prior are no longer supported and are considered End-of-Life.
- BehobenCC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT8F2cisa_csaf_ot
Update CC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT8F2 and NZ2MHG-TSNT4 to firmware version 06 or later
- BehobenSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208 (6GK5208-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208EEC (6GK5208-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G (6GK5208-0GA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216 (6GK5216-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C (6GK5216-4BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC216EEC (6GK5216-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224 (6GK5224-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204 (6GK5204-0BA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208 (6GK5208-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208EEC (6GK5208-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216 (6GK5216-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216EEC (6GK5216-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenFX5-OPCcisa_csaf_ot
FX5-OPC: Use within a LAN and block access from untrusted networks and hosts through firewalls. Restrict physical access to the product, as well as to computers and network devices located within the same network as the product. Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required. Use the IP filter function to block access from untrusted hosts. For details on the IP filter function, please refer to the MELSEC iQ-F FX5 OPC UA Module User's Manual section 4.4 "IP Filter." Do not import untrusted certificates.
- BehobenOPC UA Server Unitcisa_csaf_ot
OPC UA Server Unit: Use within a LAN and block access from untrusted networks and hosts through firewalls. Restrict physical access to the product, as well as to computers and network devices located within the same network as the product. Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required. Set a security policy other than 'None' in security setting function to prevent unauthorized access. For details on security setting function, please refer to the MELSEC iQ-R OPC UA Server Unit User's Manual (Application), section 1.1 "OPC UA Server Function".
- BehobenSINEC NMScisa_csaf_ot
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - BehobenSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenTIM 1531 IRC (6GK7543-1MX00-0XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - BehobenSCALANCE XM408-4C (6GK5408-4GP00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM408-8C (6GK5408-8GS00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM416-4C (6GK5416-4GS00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (6GK5528-0AA00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenSCALANCE XR552-12M (6GK5552-0AA00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - BehobenAFR677cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- BehobenAFS650cisa_csaf_ot
AFS650: Update to AFS 650 firmware version 9.1.10
- BehobenAFS660-Ccisa_csaf_ot
AFS660-C, AFS665-B, AFS670-V2: Update to AFS 66x firmware version 7.1.08
- BehobenAFS665-Bcisa_csaf_ot
AFS660-C, AFS665-B, AFS670-V2: Update to AFS 66x firmware version 7.1.08
- BehobenAFS670cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- BehobenAFS670-V2cisa_csaf_ot
AFS660-C, AFS665-B, AFS670-V2: Update to AFS 66x firmware version 7.1.08
- BehobenAFS675cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- BehobenAFS677cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- BehobenSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenPCU400 versions 6.5 K and belowcisa_csaf_ot
If IEC62351-3 secure for IEC104/DNP3 is used, then update to version 6.6.0 or latest
- BehobenPCU400 versions 9.4.1 and belowcisa_csaf_ot
If IEC62351-3 secure for IEC104/DNP3 is used, then update to version 9.4.2 or latest
- BehobenRelion 670 Seriescisa_csaf_ot
Update to version 2.2.2.6 or latest
- BehobenRelion 670/650 Seriescisa_csaf_ot
Update to version 2.2.4.4 or latest
- BehobenRelion 670/650/SAM600-IO Seriescisa_csaf_ot
Update to version 2.2.1.9 or latest
- BehobenGMS600cisa_csaf_ot
Upgrade to version 1.3.2
- MitigationSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
CVE-2022-4304: Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
CVE-2022-4304: Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
CVE-2022-4304: Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC Logon V1.6siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC PDM V9.1siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC PDM V9.2siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Process Historian 2019 OPC UA Serversiemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Process Historian 2020 OPC UA Serversiemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Process Historian 2022 OPC UA Serversiemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1200 CPU family (incl. SIPLUS variants)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 Software Controller V2siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 Software Controller V3siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-PLCSIM Advancedsiemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)siemens_psirt
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)siemens_psirt
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- Mitigationphoenix_contact_psirt
Do not use RSA based ciphers for encryption of network traffic, use cipher suites with forward secrecy for TLS or IPsec communication and renew vulnerable certificates frequently. Configure the incoming IPv4 packet filter carefully to protect clients from potentially malicious UDP packets.
- MitigationSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
CVE-2022-4304: Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
CVE-2022-4304: Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
CVE-2022-4304: Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationRTU500 series CMU Firmwarecisa_csaf_ot
Do not allow process control systems direct connections to the internet.
- MitigationSIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC Logon V1.6cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC PDM V9.1cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC PDM V9.2cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Process Historian 2019 OPC UA Servercisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Process Historian 2020 OPC UA Servercisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC Process Historian 2022 OPC UA Servercisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1200 CPU family (incl. SIPLUS variants)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 Software Controller V2cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-1500 Software Controller V3cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIMATIC S7-PLCSIM Advancedcisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)cisa_csaf_ot
If possible, avoid the use of RSA based certificates in TLS communication and use ECC based certificates instead
- MitigationSIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationSIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)cisa_csaf_ot
As a mitigation for vulnerable versions: disable the web server
- MitigationICONICS Suite including GENESIS64, Hyper Historian, AnalytiX, and MobileHMIcisa_csaf_ot
Additional information about the security updates may also be found in Mitsubishi Electric's security advisories:
- MitigationLumada APM Edgecisa_csaf_ot
Hitachi Energy reported that Lumada APM Edge relies on the HAProxy service (a pre-requisite component) as an API gateway, so it must be exposed to the end-users via network. For Lumada APM Edge to be accessible to the end-users, it is crucial for this service, which also utilizes OpenSSL libraries, to be updated along with its underlying operating system.
- MitigationCC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT4cisa_csaf_ot
Additionally, Mitsubishi Electric recommends that customers take the following mitigations to minimize the risk of exploitation of these vulnerabilities:
- MitigationCC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT8F2cisa_csaf_ot
Additionally, Mitsubishi Electric recommends that customers take the following mitigations to minimize the risk of exploitation of these vulnerabilities:
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Disable the use of RSA ciphers in the web server configuration; note that RSA ciphers are disabled by default
- MitigationFX5-OPCcisa_csaf_ot
Mitsbuishi Electric recommends that users update their products to the following versions:
- MitigationGT SoftGOT2000cisa_csaf_ot
GT SoftGOT2000 and OPC UA Data Collector: Do not load untrusted certificate revocation lists (CRLs).
- MitigationMX OPC Server UA (Software packaged with MC Works64)cisa_csaf_ot
MX OPC Server UA: Use recommended mitigations/workarounds
- MitigationOPC UA Data Collectorcisa_csaf_ot
GT SoftGOT2000 and OPC UA Data Collector: Do not load untrusted certificate revocation lists (CRLs).
- MitigationOPC UA Server Unitcisa_csaf_ot
Mitsbuishi Electric recommends that users update their products to the following versions:
- MitigationAFR677cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS650cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS660-Ccisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS665-Bcisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS670cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS670-V2cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS675cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS677cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationRelion 670/650 Seriescisa_csaf_ot
Apply General Mitigation Factors
- WorkaroundSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Only build and run applications from trusted sources
- Kein Fix geplantSIMATIC Logon V1.6siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC PDM V9.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC Process Historian 2019 OPC UA Serversiemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC Process Historian 2020 OPC UA Serversiemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC Logon V1.6cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC PDM V9.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC Process Historian 2019 OPC UA Servercisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC Process Historian 2020 OPC UA Servercisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantPCULogger versions 1.1.0 and belowcisa_csaf_ot
If the PCULogger program is used, then update to version 1.2.0* when available. This version is compatible with PCU400 9.4.2 and later
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.6–7.5
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
Exploits (1)
Öffentlicher Proof-of-Concept- und Exploit-Code.
betroffene Produkte (388)
Betroffene Produkte und Versionsbereiche.
- IBM InfoSphere Information Serveralle Versionencert_bundDEcpe:/a:ibm:infosphere_information_server:-
- Hitachi Energy Relion 670/650/SAM600-IO Series≤ vers:Relion_670/650/SAM600-IO/>=2.2.1|<=2.2.1.8cisa_csaf_otUS
- Hitachi Energy Relion 670/650/SAM600-IO Series≤ vers:Relion_670/650/SAM600-IO/>=2.2.5|<=2.2.5.5cisa_csaf_otUS
Advisories (44)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- SSA-203374SSA-203374: Multiple OpenSSL Vulnerabilities in SCALANCE W1750D Devices2023-03-14csaf · siemens_psirtDE
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-264814SSA-264814: Timing Based Side Channel Vulnerability in the OpenSSL RSA Decryption in SIMATIC Products2023-08-08csaf · siemens_psirtDE
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- SSA-337522SSA-337522: Multiple Vulnerabilities in TIM 1531 IRC before V2.4.82024-06-11csaf · siemens_psirtDE
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-556635SSA-556635: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.02024-04-09csaf · siemens_psirtDE
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.
- SSA-561322SSA-561322: Multiple Vulnerabilities in SIMATIC MV500 Devices before V3.3.42023-07-11csaf · siemens_psirtDE
SIMATIC MV500 devices before V3.3.4 are affected by multiple vulnerabilities in the web server and several third-party components. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-625862SSA-625862: Multiple Vulnerabilities in Third-Party Components in SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.32024-06-11csaf · siemens_psirtDE
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-699386SSA-699386: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.52023-11-14csaf · siemens_psirtDE
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-794697SSA-794697: Vulnerabilities in the Additional GNU/Linux Subsystem of the SIMATIC S7-1500 TM MFP Before V1.12023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. SIMATIC S7-1500 TM MFP V1.0 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 (https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- SSA-879734SSA-879734: Multiple Vulnerabilities in SCALANCE XM-400/XR-500 before V6.6.12024-06-11csaf · siemens_psirtDE
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-943925SSA-943925: Multiple Vulnerabilities in SINEC NMS before V2.0 SP12024-02-13csaf · siemens_psirtDE
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- VDE-2023-010PHOENIX CONTACT: FL MGUARD affected by two vulnerabilities2023-06-13csaf · phoenix_contact_psirtDE
The FL MGUARD family of devices is affected by two vulnerabilities.
- WID-SEC-W-2023-0304OpenSSL: Mehrere SchwachstellenDeutsch2023-02-07csaf · cert_bundDE
Ein entfernter, authentisierter oder anonymer Angreifer kann mehrere Schwachstellen in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder Chiffretext über ein Netzwerk wiederherzustellen.
- WID-SEC-W-2023-1350Splunk Splunk Enterprise: Mehrere Schwachstellen in Komponenten von DrittanbieternDeutsch2023-06-01csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Splunk Splunk Enterprise in diversen Komponenten von Drittanbietern ausnutzen, um einen nicht näher spezifizierten Angriff durchzuführen.
- WID-SEC-W-2023-1424Xerox FreeFlow Print Server für Solaris: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2023-1553HCL BigFix: Mehrere SchwachstellenDeutsch2023-06-22csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in HCL BigFix ausnutzen, um Sicherheitsvorkehrungen zu umgehen und um das Opfer auf bösartige Webseiten umzuleiten.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- GHSA-p52g-cm5j-mjv4openssl-src subject to Timing Oracle in RSA Decryption2023-02-08ghsa · osvUS
A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection.
- ICSA-23-075-04Siemens SCALANCE W1750D Devices2023-03-14icsa · cisa_csaf_otUS
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-23-143-02Hitachi Energy's RTU500 Series Product (UPDATE B)2023-05-05icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to crash the device being accessed or cause a denial-of-service condition.
- ICSA-23-166-11Siemens SIMATIC S7-1500 TM MFP Linux Kernel2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 ( https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- ICSA-23-194-04Siemens SIMATIC MV500 Devices2023-07-11icsa · cisa_csaf_otUS
SIMATIC MV500 devices before V3.3.4 are affected by multiple vulnerabilities in the web server and several third-party components. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-222-09Siemens SIMATIC2023-08-08icsa · cisa_csaf_otUS
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-23-229-01ICONICS and Mitsubishi Electric Products2023-08-17icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in information disclosure, denial-of-service, or remote code execution.
- ICSA-23-255-01Hitachi Energy Lumada APM Edge2023-09-12icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclosure of sensitive information.
- ICSA-23-278-03Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch (Update A)2023-10-05icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in disclosure of information stored in the product by sending specially crafted packets or could cause a denial-of service (DoS) condition by getting a legitimate user to import a specially crafted certificate.
- ICSA-23-320-08Siemens SCALANCE Family Products2023-11-14icsa · cisa_csaf_otUS
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-004-02Mitsubishi Electric Factory Automation Products2024-01-04icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could disclose information in the product or could cause denial-of-service (DoS) condition.
- ICSA-24-046-15Siemens SINEC NMS2024-02-13icsa · cisa_csaf_otUS
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- ICSA-24-165-06Siemens TIM 1531 IRC2024-06-11icsa · cisa_csaf_otUS
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-165-10Siemens SIMATIC and SIPLUS2024-06-11icsa · cisa_csaf_otUS
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-165-11Siemens SCALANCE XM-400, XR-5002024-06-11icsa · cisa_csaf_otUS
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-205-02Hitachi Energy AFS/AFR Series Products2024-07-23icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-065-01Hitachi Energy PCU4002025-02-25icsa · cisa_csaf_otUS
Hitachi Energy is aware of the multiple vulnerabilities related to various versions of OpenSSL library components used in PCU400 versions listed in this document below for IEC62351-3 secure for IEC104/DNP3 or PCULogger tool. These vulnerabilities if exploited, can cause confidentiality and availability impacts. Refer to the Recommended Immediate Actions for information about the available mitigation/remediation strategies.
- ICSA-25-160-02Hitachi Energy Relion 670, 650, SAM600-IO Series (Update A)2023-06-27icsa · cisa_csaf_otUS
Hitachi Energy is aware of the vulnerability CVE-2022-4304 in the OSS component OpenSSL, that affects the Relion 670, 650, SAM600-IO versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection. For immediate mitigation/workaround information, please refer to the General Mitigation Factors/Workarounds
- ICSA-26-141-01Hitachi Energy GMS6002023-06-27icsa · cisa_csaf_otUS
Hitachi Energy is aware of the vulnerability, CVE-2022-4304 in the OSS component OpenSSL, that affects the GMS600 versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection. For immediate mitigation /workaround information, please refer to the General Mitigation Factors/Workarounds
- RUSTSEC-2023-0007Timing Oracle in RSA Decryption2023-02-07vendor · osvUS
A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection.
auch bekannt als (6)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (57)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2022-4304cnnvd
- https://cxsecurity.com/cveshow/CVE-2022-4304/cnnvd
- https://packetstormsecurity.com/files/170921/OpenSSL-Toolkit-3.0.8.htmlcnnvd
- https://security.gentoo.org/glsa/202402-08cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0703cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0732cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.1074cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.1263cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan