CVE-2022-30937

highPriorität · verfolgen · 30EPSS 0.013 · 70. PerzentilDEEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.27% (70th) EPSS
CVSS 7.8 · high
Is it mine?
25 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenEN100 Ethernet module IEC 61850 variantsiemens_psirt

    Update to V4.37 or later version

    https://support.industry.siemens.com/cs/us/en/view/109745821/
  • BehobenEN100 Ethernet module IEC 61850 variantcisa_csaf_ot

    Update to V4.37 or later version

    https://support.industry.siemens.com/cs/us/en/view/109745821/
  • MitigationEN100 Ethernet module DNP3 IP variantsiemens_psirt

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module IEC 104 variantsiemens_psirt

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module IEC 61850 variantsiemens_psirt

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module Modbus TCP variantsiemens_psirt

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module PROFINET IO variantsiemens_psirt

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module DNP3 IP variantcisa_csaf_ot

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module IEC 104 variantcisa_csaf_ot

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module IEC 61850 variantcisa_csaf_ot

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module Modbus TCP variantcisa_csaf_ot

    Disable web service within the device configuration if it is not used

  • MitigationEN100 Ethernet module PROFINET IO variantcisa_csaf_ot

    Disable web service within the device configuration if it is not used

  • WorkaroundEN100 Ethernet module DNP3 IP variantsiemens_psirt

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module IEC 104 variantsiemens_psirt

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module IEC 61850 variantsiemens_psirt

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module Modbus TCP variantsiemens_psirt

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module PROFINET IO variantsiemens_psirt

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module DNP3 IP variantcisa_csaf_ot

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module IEC 104 variantcisa_csaf_ot

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module IEC 61850 variantcisa_csaf_ot

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module Modbus TCP variantcisa_csaf_ot

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • WorkaroundEN100 Ethernet module PROFINET IO variantcisa_csaf_ot

    Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions

  • Kein Fix geplantEN100 Ethernet module DNP3 IP variantsiemens_psirt

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module IEC 104 variantsiemens_psirt

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module Modbus TCP variantsiemens_psirt

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module PROFINET IO variantsiemens_psirt

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module DNP3 IP variantcisa_csaf_ot

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module IEC 104 variantcisa_csaf_ot

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module Modbus TCP variantcisa_csaf_ot

    Currently no fix is planned

  • Kein Fix geplantEN100 Ethernet module PROFINET IO variantcisa_csaf_ot

    Currently no fix is planned

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.6
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.9–8.6

v2.07.8highAV:N/AC:L/Au:N/C:N/I:N/A:Cprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 6.9
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 3.6
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (25)

Betroffene Produkte und Versionsbereiche.

20 von 25 angezeigt
05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-693555SSA-693555: Memory Corruption Vulnerability in EN100 Ethernet Module2022-06-14csaf · siemens_psirtDE

    EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30937). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.

  • ICSA-22-167-05Siemens EN100 Ethernet Module2022-06-14icsa · cisa_csaf_otUS

    EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30937). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2022-06-14geändert 2026-06-17
09

Referenzen (6)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan