CVE-2022-30937
highPriorität · verfolgen · 30EPSS 0.013 · 70. PerzentilDEEUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenEN100 Ethernet module IEC 61850 variantsiemens_psirt
Update to V4.37 or later version
https://support.industry.siemens.com/cs/us/en/view/109745821/ - BehobenEN100 Ethernet module IEC 61850 variantcisa_csaf_ot
Update to V4.37 or later version
https://support.industry.siemens.com/cs/us/en/view/109745821/ - MitigationEN100 Ethernet module DNP3 IP variantsiemens_psirt
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module IEC 104 variantsiemens_psirt
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module IEC 61850 variantsiemens_psirt
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module Modbus TCP variantsiemens_psirt
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module PROFINET IO variantsiemens_psirt
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module DNP3 IP variantcisa_csaf_ot
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module IEC 104 variantcisa_csaf_ot
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module IEC 61850 variantcisa_csaf_ot
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module Modbus TCP variantcisa_csaf_ot
Disable web service within the device configuration if it is not used
- MitigationEN100 Ethernet module PROFINET IO variantcisa_csaf_ot
Disable web service within the device configuration if it is not used
- WorkaroundEN100 Ethernet module DNP3 IP variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module IEC 104 variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module IEC 61850 variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module Modbus TCP variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module PROFINET IO variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module DNP3 IP variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module IEC 104 variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module IEC 61850 variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module Modbus TCP variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- WorkaroundEN100 Ethernet module PROFINET IO variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions
- Kein Fix geplantEN100 Ethernet module DNP3 IP variantsiemens_psirt
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module IEC 104 variantsiemens_psirt
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module Modbus TCP variantsiemens_psirt
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module PROFINET IO variantsiemens_psirt
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module DNP3 IP variantcisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module IEC 104 variantcisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module Modbus TCP variantcisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantEN100 Ethernet module PROFINET IO variantcisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.9–8.6
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (25)
Betroffene Produkte und Versionsbereiche.
- siemens en100 ethernet module dnp3 firmwarealle VersionennvdUScpe:2.3:o:siemens:en100_ethernet_module_dnp3_firmware:*:*:*:*:*:*:*:*
- siemens en100 ethernet module iec 104 firmwarealle VersionennvdUScpe:2.3:o:siemens:en100_ethernet_module_iec_104_firmware:*:*:*:*:*:*:*:*
- siemens en100 ethernet module iec 61850 firmware< 4.37nvdUScpe:2.3:o:siemens:en100_ethernet_module_iec_61850_firmware:*:*:*:*:*:*:*:*
- siemens en100 ethernet module modbus tcp firmwarealle VersionennvdUScpe:2.3:o:siemens:en100_ethernet_module_modbus_tcp_firmware:*:*:*:*:*:*:*:*
- siemens en100 ethernet module profinet io firmwarealle VersionennvdUScpe:2.3:o:siemens:en100_ethernet_module_profinet_io_firmware:*:*:*:*:*:*:*:*
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-693555SSA-693555: Memory Corruption Vulnerability in EN100 Ethernet Module2022-06-14csaf · siemens_psirtDE
EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30937). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
- ICSA-22-167-05Siemens EN100 Ethernet Module2022-06-14icsa · cisa_csaf_otUS
EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30937). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-693555.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-30937/cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-167-05cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.2995cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-693555.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-693555.pdfPatchVendor Advisorynvd