CVE-2022-30065
mediumPriorität · verfolgen · 31EPSS 0.013 · 69. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
A use-after-free in Busybox 1.35-x's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSCALANCE SC622-2C (6GK5622-2GS00-2AC2)siemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC626-2C (6GK5626-2GS00-2AC2)siemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC632-2C (6GK5632-2GS00-2AC2)siemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC636-2C (6GK5636-2GS00-2AC2)siemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC642-2C (6GK5642-2GS00-2AC2)siemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC646-2C (6GK5646-2GS00-2AC2)siemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenRUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenRUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M804PB (6GK5804-0AP00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M874-2 (6GK5874-2AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M874-3 (6GK5874-3AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-4 (6GK5876-4AA10-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE S615 (6GK5615-0AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE S615 EEC (6GK5615-0AA01-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817513/ - BehobenSIMATIC S7-1500 TM MFP - BIOSsiemens_psirt
Update to V1.3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109945851/ - Behobenphoenix_contact_psirt
Update to the latest 2023.0.0 LTS Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- BehobenSCALANCE SC622-2C (6GK5622-2GS00-2AC2)cisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC626-2C (6GK5626-2GS00-2AC2)cisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC632-2C (6GK5632-2GS00-2AC2)cisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC636-2C (6GK5636-2GS00-2AC2)cisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC642-2C (6GK5642-2GS00-2AC2)cisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenSCALANCE SC646-2C (6GK5646-2GS00-2AC2)cisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814276/ - BehobenRUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenRUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M804PB (6GK5804-0AP00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M874-2 (6GK5874-2AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M874-3 (6GK5874-3AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-4 (6GK5876-4AA10-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE S615 (6GK5615-0AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE S615 EEC (6GK5615-0AA01-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/document/109817007/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817513/ - BehobenSIMATIC S7-1500 TM MFP - BIOScisa_csaf_ot
Update to V1.3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109945851/ - Mitigationphoenix_contact_psirt
Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note: Measures to protect network-capable devices with Ethernet connection
- WorkaroundSIMATIC S7-1500 TM MFP - BIOSsiemens_psirt
Only build and run applications from trusted sources
- WorkaroundSIMATIC S7-1500 TM MFP - BIOScisa_csaf_ot
Only build and run applications from trusted sources
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–8.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (38)
Betroffene Produkte und Versionsbereiche.
- siemens scalance sc622-2c firmware< 3.0nvdUScpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*
Advisories (11)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-333517SSA-333517: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.02022-12-13csaf · siemens_psirtDE
Multiple vulnerabilities affecting various third-party components of the SCALANCE SC-600 family could allow an attacker to cause a denial of service condition, corrupt memory or potentially execute custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-419740SSA-419740: Multiple Third-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.22023-03-14csaf · siemens_psirtDE
Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special elements to improper handling of commands under certain circumstances, that could lead to code injection and denial of service. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-558014SSA-558014: Third-Party Component Vulnerabilities in SCALANCE XCM332 before V2.22023-04-11csaf · siemens_psirtDE
Multiple vulnerabilities in the third-party components cURL, BusyBox, libtirpc, Expat as well as in the Linux Kernel could allow an attacker to impact the SCALANCE XCM332 device's confidentiality, integrity and availability. Siemens has released an update for the SCALANCE XCM332 and recommends to update to the latest version.
- SSA-831302SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.02023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.
- VDE-2023-001PHOENIX CONTACT: Multiple Vulnerabilities in PLCnext Firmware2023-02-14csaf · phoenix_contact_psirtDE
A new LTS Firmware release fixes known vulnerabilities in used open-source libraries. In addition, the following improvements have been implemented: HMI - Hardening against DoS attacks. - Hardening against memory leak problems in case of network attacks. WBM - Umlauts in the password of the 'User Manager' were not handled correctly. The password rule for upper and lower case was not followed. This could lead to unintentionally weaker passwords.- Hardening of WBM against Cross-Site-Scripting. User Manager - In security notifications 'SecurityToken' was always displayed as '0000000' when creating or modifying users.- Hardening of Trust and Identity Stores.
- WID-SEC-W-2022-2211BusyBox: Schwachstelle ermöglicht Denial of ServiceDeutsch2022-05-18csaf · cert_bundDE
Ein Angreifer kann eine Schwachstelle in BusyBox ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- ICSA-22-349-18Siemens SCALANCE SC-600 Family2022-12-13icsa · cisa_csaf_otUS
Multiple vulnerabilities affecting various third-party components of the SCALANCE SC-600 family could allow an attacker to cause a denial of service condition, corrupt memory or potentially execute custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-075-01Siemens SCALANCE, RUGGEDCOM Third-Party2023-03-14icsa · cisa_csaf_otUS
Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special elements to improper handling of commands under certain circumstances, that could lead to code injection and denial of service. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-103-09Siemens SCALANCE XCM3322023-04-11icsa · cisa_csaf_otUS
Multiple vulnerabilities in the third-party components cURL, BusyBox, libtirpc, Expat as well as in the Linux Kernel could allow an attacker to impact the SCALANCE XCM332 device's confidentiality, integrity and availability. Siemens has released an update for the SCALANCE XCM332 and recommends to update to the latest version.
- ICSA-23-166-10Siemens SIMATIC S7-1500 TM MFP BIOS2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (11)
Externe Belege — Patches, Meldungen, Analysen.
- https://bugs.busybox.net/show_bug.cgi?id=14781cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-333517.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-30065/cnnvd
- https://vigilance.fr/vulnerability/BusyBox-reuse-after-free-via-Awk-Applet-39999cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.6310cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.6430cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.2163cnnvd
- https://bugs.busybox.net/show_bug.cgi?id=14781enisa_euvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan