CVE-2022-30065

mediumPriorität · verfolgen · 31EPSS 0.013 · 69. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.25% (69th) EPSS
CVSS 6.8 · medium
Is it mine?
38 products
Prüfe deine Angriffsfläche
Who says so?
8 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · bewertet 2026-10-27

A use-after-free in Busybox 1.35-x's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–8.8

v2.06.8mediumAV:N/AC:M/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 6.4
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.18.8highAV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HsecondaryAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · Phoenix Contact PSIRT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (38)

Betroffene Produkte und Versionsbereiche.

06

Advisories (11)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-333517SSA-333517: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.02022-12-13csaf · siemens_psirtDE

    Multiple vulnerabilities affecting various third-party components of the SCALANCE SC-600 family could allow an attacker to cause a denial of service condition, corrupt memory or potentially execute custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • SSA-419740SSA-419740: Multiple Third-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.22023-03-14csaf · siemens_psirtDE

    Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special elements to improper handling of commands under certain circumstances, that could lead to code injection and denial of service. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • SSA-558014SSA-558014: Third-Party Component Vulnerabilities in SCALANCE XCM332 before V2.22023-04-11csaf · siemens_psirtDE

    Multiple vulnerabilities in the third-party components cURL, BusyBox, libtirpc, Expat as well as in the Linux Kernel could allow an attacker to impact the SCALANCE XCM332 device's confidentiality, integrity and availability. Siemens has released an update for the SCALANCE XCM332 and recommends to update to the latest version.

  • SSA-831302SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.02023-06-13csaf · siemens_psirtDE

    Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.

  • VDE-2023-001PHOENIX CONTACT: Multiple Vulnerabilities in PLCnext Firmware2023-02-14csaf · phoenix_contact_psirtDE

    A new LTS Firmware release fixes known vulnerabilities in used open-source libraries. In addition, the following improvements have been implemented: HMI - Hardening against DoS attacks. - Hardening against memory leak problems in case of network attacks. WBM - Umlauts in the password of the 'User Manager' were not handled correctly. The password rule for upper and lower case was not followed. This could lead to unintentionally weaker passwords.- Hardening of WBM against Cross-Site-Scripting. User Manager - In security notifications 'SecurityToken' was always displayed as '0000000' when creating or modifying users.- Hardening of Trust and Identity Stores.

  • WID-SEC-W-2022-2211BusyBox: Schwachstelle ermöglicht Denial of ServiceDeutsch2022-05-18csaf · cert_bundDE

    Ein Angreifer kann eine Schwachstelle in BusyBox ausnutzen, um einen Denial of Service Angriff durchzuführen.

  • WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE

    Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.

  • ICSA-22-349-18Siemens SCALANCE SC-600 Family2022-12-13icsa · cisa_csaf_otUS

    Multiple vulnerabilities affecting various third-party components of the SCALANCE SC-600 family could allow an attacker to cause a denial of service condition, corrupt memory or potentially execute custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-075-01Siemens SCALANCE, RUGGEDCOM Third-Party2023-03-14icsa · cisa_csaf_otUS

    Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special elements to improper handling of commands under certain circumstances, that could lead to code injection and denial of service. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-103-09Siemens SCALANCE XCM3322023-04-11icsa · cisa_csaf_otUS

    Multiple vulnerabilities in the third-party components cURL, BusyBox, libtirpc, Expat as well as in the Linux Kernel could allow an attacker to impact the SCALANCE XCM332 device's confidentiality, integrity and availability. Siemens has released an update for the SCALANCE XCM332 and recommends to update to the latest version.

  • ICSA-23-166-10Siemens SIMATIC S7-1500 TM MFP BIOS2023-06-13icsa · cisa_csaf_otUS

    Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.

07

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

10

Referenzen (11)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan