CVE-2022-29187
mediumPriorität · verfolgen · 31EPSS 0.004 · 39. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
Git is a distributed revision control system. Git prior to versions 2.37.1, 2.36.2, 2.35.4, 2.34.4, 2.33.4, 2.32.3, 2.31.4, and 2.30.5, is vulnerable to privilege escalation in all platforms. An unsuspecting user could still be affected by the issue reported in CVE-2022-24765, for example when navigating as root into a shared tmp directory that is owned by them, but where an attacker could create a git repository. Versions 2.37.1, 2.36.2, 2.35.4, 2.34.4, 2.33.4, 2.32.3, 2.31.4, and 2.30.5 contain a patch for this issue. The simplest way to avoid being affected by the exploit described in the example is to avoid running git as root (or an Administrator in Windows), and if needed to reduce its use to a minimum. While a generic workaround is not possible, a system could be hardened from the exploit described in the example by removing any such repository if it exists already and creating one as root to block any future attacks.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - Behobenphoenix_contact_psirt
Update to the latest 2023.0.0 LTS Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- BehobenPLCnext Engineerphoenix_contact_psirt
Update PLCnext Engineer to 2023.6.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - Mitigationphoenix_contact_psirt
Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note: Measures to protect network-capable devices with Ethernet connection
- MitigationPLCnext Engineerphoenix_contact_psirt
To mitigate aforementioned vulnerabilities the integrity and authenticity of the git configuration data must be ensured. Otherwise, we kindly advise you to refrain from using the version control feature in version lower than 2023.6
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.9–7.8
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (88)
Betroffene Produkte und Versionsbereiche.
- IBM InfoSphere Information Serveralle Versionencert_bundDEcpe:/a:ibm:infosphere_information_server:-
Advisories (7)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-806742SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.42024-02-13csaf · siemens_psirtDE
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- VDE-2023-001PHOENIX CONTACT: Multiple Vulnerabilities in PLCnext Firmware2023-02-14csaf · phoenix_contact_psirtDE
A new LTS Firmware release fixes known vulnerabilities in used open-source libraries. In addition, the following improvements have been implemented: HMI - Hardening against DoS attacks. - Hardening against memory leak problems in case of network attacks. WBM - Umlauts in the password of the 'User Manager' were not handled correctly. The password rule for upper and lower case was not followed. This could lead to unintentionally weaker passwords.- Hardening of WBM against Cross-Site-Scripting. User Manager - In security notifications 'SecurityToken' was always displayed as '0000000' when creating or modifying users.- Hardening of Trust and Identity Stores.
- VDE-2023-016Phoenix Contact: PLCnext Engineer Vulnerabilities in LibGit2Sharp/LibGit22023-08-08csaf · phoenix_contact_psirtDE
Several vulnerabilities have been discovered in the LibGit2Sharp or underlying LibGit2 library.This open-source component is widely used in a lot of products worldwide.The product is vulnerable to remote code execution, privilege escalation and tampering.PLCnext Engineer is using the LibGit2Sharp library to provide version control capabilities.
- WID-SEC-W-2022-0664git: Mehrere SchwachstellenDeutsch2022-07-12csaf · cert_bundDE
Ein entfernter, anonymer oder lokaler Angreifer kann mehrere Schwachstellen in git ausnutzen, um Sicherheitsvorkehrungen zu umgehen und beliebigen Code auszuführen.
- WID-SEC-W-2023-0561Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2023-03-02csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- ICSA-24-046-11Siemens SCALANCE XCM-/XRM-3002024-02-13icsa · cisa_csaf_otUS
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (58)
Externe Belege — Patches, Meldungen, Analysen.
- http://seclists.org/fulldisclosure/2022/Nov/1cnnvd
- http://www.openwall.com/lists/oss-security/2022/07/14/1cnnvd
- https://cxsecurity.com/cveshow/CVE-2022-29187/cnnvd
- https://github.blog/2022-04-12-git-security-vulnerability-announcedcnnvd
- https://github.com/git/git/security/advisories/GHSA-j342-m5hw-rr3vcnnvd
- https://lists.debian.org/debian-lts-announce/2022/12/msg00025.htmlcnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/DDI325LOO2XBDDKLINOAQJEG6MHAURZE/cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/DIKWISWUDFT2FAITYIA6372BVLH3OOOC/cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan