CVE-2022-27220
mediumPriorität · verfolgen · 17EPSS 0.007 · 52. PerzentilDEEUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 6220. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSINEMA Remote Connect Serversiemens_psirt
Update to V3.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793790/ - BehobenSINEMA Remote Connect Servercisa_csaf_ot
Update to V3.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793790/
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (6)
Betroffene Produkte und Versionsbereiche.
- siemens sinema remote connect server< 3.0nvdUScpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*
- siemens sinema remote connect server= 3.0nvdUScpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-911567SSA-911567: Missing HTTP headers in SINEMA Remote Connect Server before V3.0 SP22022-06-14csaf · siemens_psirtDE
SINEMA Remote Connect Server is missing HTTP security headers on the web server. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version.
- ICSA-22-167-07Siemens SINEMA Remote Connect Server2022-06-14icsa · cisa_csaf_otUS
SINEMA Remote Connect Server is missing HTTP security headers on the web server. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-911567.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-27220/cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-167-07cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.2979cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-911567.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-911567.pdfPatchVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan