CVE-2022-27219

mediumPriorität · verfolgen · 17EPSS 0.007 · 52. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.68% (52nd) EPSS
CVSS 4.3 · medium
Is it mine?
6 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 443. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

4.3
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.04.3mediumAV:N/AC:M/Au:N/C:N/I:P/A:Nprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 2.9
v3.14.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 1.4
v3.14.2mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.14.2mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.14mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (6)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-911567SSA-911567: Missing HTTP headers in SINEMA Remote Connect Server before V3.0 SP22022-06-14csaf · siemens_psirtDE

    SINEMA Remote Connect Server is missing HTTP security headers on the web server. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version.

  • ICSA-22-167-07Siemens SINEMA Remote Connect Server2022-06-14icsa · cisa_csaf_otUS

    SINEMA Remote Connect Server is missing HTTP security headers on the web server. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2022-06-14geändert 2026-06-17
09

Referenzen (6)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan