CVE-2022-26647
highPriorität · verfolgen · 30OT-Risiko · erhöhtEPSS 0.012 · 67. PerzentilDEEUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB10-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204-2 (6GK5204-2BB10-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2FM (6GK5204-2BB11-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2LD (6GK5204-2BC10-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2TS (6GK5204-2BB10-2CA2)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204IRT (6GK5204-0BA00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT (6GK5204-0BA10-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X206-1 (6GK5206-1BB10-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X206-1LD (6GK5206-1BC10-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X208 (6GK5208-0BA10-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X208PRO (6GK5208-0HA10-2AA6)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X212-2 (6GK5212-2BB00-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X212-2LD (6GK5212-2BC00-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X216 (6GK5216-0BA00-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X224 (6GK5224-0BA00-2AA3)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204 (6GK5204-0BA00-2AF2)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF204-2 (6GK5204-2BC00-2AF2)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204IRT (6GK5204-0BA00-2BF2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF206-1 (6GK5206-1BC00-2AF2)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF208 (6GK5208-0BA00-2AF2)siemens_psirt
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB10-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204-2 (6GK5204-2BB10-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2FM (6GK5204-2BB11-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2LD (6GK5204-2BC10-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204-2TS (6GK5204-2BB10-2CA2)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X204IRT (6GK5204-0BA00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT (6GK5204-0BA10-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X206-1 (6GK5206-1BB10-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X206-1LD (6GK5206-1BC10-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X208 (6GK5208-0BA10-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X208PRO (6GK5208-0HA10-2AA6)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X212-2 (6GK5212-2BB00-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X212-2LD (6GK5212-2BC00-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X216 (6GK5216-0BA00-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE X224 (6GK5224-0BA00-2AA3)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204 (6GK5204-0BA00-2AF2)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF204-2 (6GK5204-2BC00-2AF2)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204IRT (6GK5204-0BA00-2BF2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF206-1 (6GK5206-1BC00-2AF2)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - BehobenSCALANCE XF208 (6GK5208-0BA00-2AF2)cisa_csaf_ot
Update to V5.2.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811753/ - WorkaroundSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2IRT (6GK5202-2BB10-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2 (6GK5204-2BB10-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2FM (6GK5204-2BB11-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2LD (6GK5204-2BC10-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2TS (6GK5204-2BB10-2CA2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204IRT (6GK5204-0BA00-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204IRT (6GK5204-0BA10-2BA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X206-1 (6GK5206-1BB10-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X206-1LD (6GK5206-1BC10-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X208 (6GK5208-0BA10-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X208PRO (6GK5208-0HA10-2AA6)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X212-2 (6GK5212-2BB00-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X212-2LD (6GK5212-2BC00-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X216 (6GK5216-0BA00-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X224 (6GK5224-0BA00-2AA3)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204 (6GK5204-0BA00-2AF2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204-2 (6GK5204-2BC00-2AF2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204IRT (6GK5204-0BA00-2BF2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF206-1 (6GK5206-1BC00-2AF2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF208 (6GK5208-0BA00-2AF2)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2IRT (6GK5202-2BB10-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2 (6GK5204-2BB10-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2FM (6GK5204-2BB11-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2LD (6GK5204-2BC10-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204-2TS (6GK5204-2BB10-2CA2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204IRT (6GK5204-0BA00-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204IRT (6GK5204-0BA10-2BA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X206-1 (6GK5206-1BB10-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X206-1LD (6GK5206-1BC10-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X208 (6GK5208-0BA10-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X208PRO (6GK5208-0HA10-2AA6)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X212-2 (6GK5212-2BB00-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X212-2LD (6GK5212-2BC00-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X216 (6GK5216-0BA00-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X224 (6GK5224-0BA00-2AA3)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204 (6GK5204-0BA00-2AF2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204-2 (6GK5204-2BC00-2AF2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF204IRT (6GK5204-0BA00-2BF2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF206-1 (6GK5206-1BC00-2AF2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XF208 (6GK5208-0BA00-2AF2)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 6.4–9.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (151)
Betroffene Produkte und Versionsbereiche.
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-310038SSA-310038: Multiple Vulnerabilities in SCALANCE X Switch Devices2022-07-12csaf · siemens_psirtDE
Several SCALANCE X switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.
- ICSA-22-195-01Siemens SCALANCE X Switch Devices2022-07-12icsa · cisa_csaf_otUS
Several SCALANCE X switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-26647/cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-195-01cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2022071408cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdfPatchVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan