CVE-2022-26507
highPriorität · verfolgen · 40EPSS 0.024 · 84. PerzentilEURUUSEPSS · bewertet 2026-10-27
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationEcoStruxure Control Expertcisa_csaf_ot
AT&T Labs have stated this software is longer supported and recommends vendors to move away from using it.
- MitigationEcoStruxure Process Expertcisa_csaf_ot
AT&T Labs have stated this software is longer supported and recommends vendors to move away from using it.
- MitigationSCADAPack RemoteConnect for x70cisa_csaf_ot
AT&T Labs have stated this software is longer supported and recommends vendors to move away from using it.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.5–9.8
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (15)
Betroffene Produkte und Versionsbereiche.
- Schneider Electric Software, LLC EcoStruxure Control Expert< 15.1 HF001 (including former Unity Pro)cisa_csaf_otUS
- Schneider Electric Software, LLC EcoStruxure Process Expert< 2021 (including former HDCS)cisa_csaf_otUS
- schneider-electric ecostruxure control expert< 15.1nvdUScpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure control expert= 15.1nvdUScpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure process expert< 2021nvdUScpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*
- schneider-electric remoteconnectalle VersionennvdUScpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-22-223-03Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x702022-08-11icsa · cisa_csaf_otUS
The successful exploitation of these vulnerabilities on the affected products could lead to the execution of malicious files, which could result in code execution with elevated privileges.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (9)
Externe Belege — Patches, Meldungen, Analysen.
- https://Claroty.comcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-26507/cnnvd
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-223-03cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.4036cnnvd
- https://Claroty.comenisa_euvd
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02enisa_euvd
- https://Claroty.comNot ApplicableThird Party Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan