CVE-2022-25754
mediumPriorität · verfolgen · 35EPSS 0.005 · 45. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSCALANCE X302-7 EEC (230V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (230V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (24V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (24V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 230V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 230V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 24V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 24V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X304-2FEsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X306-1LD FEsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (230V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (230V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (24V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (24V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 230V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 230V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 24V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 24V, coated)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-3siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-3LDsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2LDsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2LHsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2LH+siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2Msiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2M PoEsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2M TSsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X310siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X310FEsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X320-1 FEsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X320-1-2LD FEsiemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X408-2siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (230V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (230V, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (24V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (24V, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M TS (24V)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (24V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (24V, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (230V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (230V, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (24V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (24V, ports on rear)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE TS (24V, ports on front)siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSIPLUS NET SCALANCE X308-2siemens_psirt
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (230V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (230V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (24V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (24V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 230V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 230V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 24V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X302-7 EEC (2x 24V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X304-2FEcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X306-1LD FEcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (230V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (230V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (24V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (24V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 230V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 230V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 24V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-2 EEC (2x 24V, coated)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-3cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X307-3LDcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2LDcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2LHcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2LH+cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2Mcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2M PoEcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X308-2M TScisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X310cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X310FEcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X320-1 FEcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X320-1-2LD FEcisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE X408-2cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (230V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (230V, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (24V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M (24V, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-12M TS (24V)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (24V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (24V, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (230V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (230V, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (24V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE (24V, ports on rear)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSCALANCE XR324-4M PoE TS (24V, ports on front)cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - BehobenSIPLUS NET SCALANCE X308-2cisa_csaf_ot
Update to V4.1.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808359/ - WorkaroundSCALANCE X302-7 EEC (230V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (230V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (24V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (24V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 230V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 230V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 24V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 24V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X304-2FEsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X306-1LD FEsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (230V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (230V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (24V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (24V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 230V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 230V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 24V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 24V, coated)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-3siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-3LDsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2LDsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2LHsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2LH+siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2Msiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2M PoEsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2M TSsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X310siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X310FEsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X320-1 FEsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X320-1-2LD FEsiemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X408-2siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (230V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (230V, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (24V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (24V, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M TS (24V)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (24V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (24V, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 24V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 24V, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (230V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (230V, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (24V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (24V, ports on rear)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE TS (24V, ports on front)siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSIPLUS NET SCALANCE X308-2siemens_psirt
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (230V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (230V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (24V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (24V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 230V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 230V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 24V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X302-7 EEC (2x 24V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X304-2FEcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X306-1LD FEcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (230V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (230V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (24V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (24V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 230V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 230V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 24V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-2 EEC (2x 24V, coated)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-3cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X307-3LDcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2LDcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2LHcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2LH+cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2Mcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2M PoEcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X308-2M TScisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X310cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X310FEcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X320-1 FEcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X320-1-2LD FEcisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE X408-2cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (230V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (230V, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (24V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M (24V, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-12M TS (24V)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (24V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (24V, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 24V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M EEC (2x 24V, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (230V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (230V, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (24V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE (24V, ports on rear)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSCALANCE XR324-4M PoE TS (24V, ports on front)cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
- WorkaroundSIPLUS NET SCALANCE X308-2cisa_csaf_ot
Deactivate the webserver if not required, and if deactivation is supported by the product
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–8.8
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (241)
Betroffene Produkte und Versionsbereiche.
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-836527SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices2022-04-12csaf · siemens_psirtDE
Several SCALANCE X-300 switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial of service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-22-104-09Siemens SCALANCE X-300 Switches2022-04-12icsa · cisa_csaf_otUS
Several SCALANCE X-300 switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial of service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-25754/cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdfMitigationPatchVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan