CVE-2022-23448

highPriorität · verfolgen · 31EPSS 0.002 · 16. PerzentilDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.25% (16th) EPSS
CVSS 7.2 · high
Is it mine?
14 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.07.2highAV:L/AC:L/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 10
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.3highCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.3highAV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.3highCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (14)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-655554SSA-655554: Multiple Vulnerabilities in SIMATIC Energy Manager before V7.3 Update 12022-04-12csaf · siemens_psirtDE

    SIMATIC Energy Manager is affected by multiple vulnerabilities that could allow an attacker to gain local privilege escalation, local code execution or remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-22-104-11Siemens SIMATIC Energy Manager2022-04-12icsa · cisa_csaf_otUS

    SIMATIC Energy Manager is affected by multiple vulnerabilities that could allow an attacker to gain local privilege escalation, local code execution or remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (7)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan