CVE-2022-23102

mediumPriorität · verfolgen · 26EPSS 0.047 · 92. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
4.72% (92nd) EPSS
CVSS 5.8 · medium
Is it mine?
6 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.05.8mediumAV:N/AC:M/Au:N/C:P/I:P/A:Nprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 4.9
v3.16.1mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 2.7
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.16.1mediumAV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nsecondary · FSTEC (BDU) RU
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:Fsecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (6)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-654775SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server2022-02-08csaf · siemens_psirtDE

    An open redirect vulnerability in SINEMA Remote Connect Server could allow an attacker to steal logon credentials with a specially crafted malicious link. Siemens has released software update for the SINEMA Remote Connect Server and recommends to update to the latest version.

  • ICSA-22-041-04Siemens SINEMA Remote Connect Server2022-02-08icsa · cisa_csaf_otUS

    An open redirect vulnerability in SINEMA Remote Connect Server could allow an attacker to steal logon credentials with a specially crafted malicious link. Siemens has released software update for the SINEMA Remote Connect Server and recommends to update to the latest version.

06

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (13)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan