CVE-2022-0778
mediumPriorität · beachten · 66EPSS 0.732 · 99. PerzentilExploit · PoCDEEUNLRUUSEPSS · bewertet 2026-10-22
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSICK SIM2000-2 P Track & Trace with Firmware <1.7.0sick_psirt
The recommended solution is to update the firmware to a version >= 1.7.0 as soon as possible.
- BehobenSICK SIM2000ST-E with Firmware <1.7.0sick_psirt
The recommended solution is to update the firmware to a version >= 1.7.0 as soon as possible.
- BehobenSICK SIM2x00 with Firmware <1.2.0sick_psirt
The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible.
- BehobenSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenBFCClientsiemens_psirt
Update to V2.17 or later version. Contact customer support to obtain the update
- BehobenSIDIS Primesiemens_psirt
Update to V4.0.400 or later version
- BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenIndustrial Edge - OPC UA Connectorsiemens_psirt
Use the Edge Management System to update to V1.7 or later version
https://www.siemens.com/industrial-edge-marketplace/ - BehobenIndustrial Edge - SIMATIC S7 Connector Appsiemens_psirt
Use the Edge Management System to update to V1.7 or later version
https://www.siemens.com/industrial-edge-marketplace/ - BehobenRUGGEDCOM CROSSBOW Station Access Controller (SAC)siemens_psirt
Update ROX II to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenRUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenRUGGEDCOM ROX MX5000siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX MX5000REsiemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1400siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1500siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1501siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1510siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1511siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1512siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1524siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1536siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX5000siemens_psirt
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenSCALANCE LPE9403 (6GK5998-3GS00-2AC2)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811123/ - BehobenSCALANCE M804PB (6GK5804-0AP00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M874-2 (6GK5874-2AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M874-3 (6GK5874-3AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-3 (6GK5876-3AA02-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-4 (6GK5876-4AA10-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)siemens_psirt
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE SC622-2C (6GK5622-2GS00-2AC2)siemens_psirt
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC632-2C (6GK5632-2GS00-2AC2)siemens_psirt
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC636-2C (6GK5636-2GS00-2AC2)siemens_psirt
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC642-2C (6GK5642-2GS00-2AC2)siemens_psirt
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC646-2C (6GK5646-2GS00-2AC2)siemens_psirt
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
Update to V8.7.1.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816886/ - BehobenSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
Update to V8.7.1.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816886/ - BehobenSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
Update to V8.7.1.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816886/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB10-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT (6GK5204-0BA00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT (6GK5204-0BA10-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X304-2FE (6GK5304-2BD00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3 (6GK5307-3BL00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3 (6GK5307-3BL10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3LD (6GK5307-3BM00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3LD (6GK5307-3BM10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2 (6GK5308-2FL00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2 RD (inkl. SIPLUS variants)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LD (6GK5308-2FM00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LD (6GK5308-2FM10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH (6GK5308-2FN00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH (6GK5308-2FN10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M (6GK5308-2GG00-2AA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M (6GK5308-2GG10-2AA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M TS (6GK5308-2GG00-2CA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M TS (6GK5308-2GG10-2CA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310 (6GK5310-0FA00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310 (6GK5310-0FA10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310FE (6GK5310-0BA00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310FE (6GK5310-0BA10-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X320-1 FE (6GK5320-1BD00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X408-2 (6GK5408-2FD00-2AA2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208 (6GK5208-0BA00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208EEC (6GK5208-0BA00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G (6GK5208-0GA00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216 (6GK5216-0BA00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C (6GK5216-4BS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216EEC (6GK5216-0BA00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224 (6GK5224-0BA00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204 (6GK5204-0BA00-2GF2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204IRT (6GK5204-0BA00-2BF2)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XM408-4C (6GK5408-4GP00-2AM2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM408-8C (6GK5408-8GS00-2AM2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM416-4C (6GK5416-4GS00-2AM2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XP208 (6GK5208-0HA00-2AS6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP208EEC (6GK5208-0HA00-2ES6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216 (6GK5216-0HA00-2AS6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216EEC (6GK5216-0HA00-2ES6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2)siemens_psirt
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (6GK5528-0AA00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (6GK5552-0AA00-2AR2)siemens_psirt
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-1 (6GK7243-1BX30-0XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)siemens_psirt
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIMATIC CP 1543-1 (6GK7543-1AX00-0XE0)siemens_psirt
Update to V3.0.37 or later version
https://support.industry.siemens.com/cs/ww/en/view/109828349/ - BehobenSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)siemens_psirt
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIMATIC CP 1545-1 (6GK7545-1GX00-0XE0)siemens_psirt
Update to V1.1.80 or later version
https://support.industry.siemens.com/cs/ww/en/view/109994056/ - BehobenSIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0)siemens_psirt
Update to V3.3.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817938/ - BehobenSIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)siemens_psirt
Update to V1.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812235/ - BehobenSIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)siemens_psirt
Update to V1.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812235/ - BehobenSIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773914/ - BehobenSIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773914/ - BehobenSIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)siemens_psirt
Update to V21.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109759122/ - BehobenSIMATIC HMI Unified Comfort Panels familysiemens_psirt
Update to V18 or later version
https://support.industry.siemens.com/cs/ww/en/view/109746530/ - BehobenSIMATIC Logon V1.6siemens_psirt
Update to V1.6 Upd6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805072/ - BehobenSIMATIC MV540 H (6GF3540-0GE10)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV540 S (6GF3540-0CD10)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV550 H (6GF3550-0GE10)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV550 S (6GF3550-0CD10)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV560 U (6GF3560-0LE10)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV560 X (6GF3560-0HE10)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC NET PC Software V16siemens_psirt
Update to V16 Update 6 or later version
- BehobenSIMATIC NET PC Software V17siemens_psirt
Update to V17 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820674/ - BehobenSIMATIC PCS 7 TeleControlsiemens_psirt
Update to V9.1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826159/ - BehobenSIMATIC PCS 7 V9.1siemens_psirt
Update to V9.1 SP2 UC04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - BehobenSIMATIC PCS neo (Administration Console)siemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814551/ - BehobenSIMATIC PDMsiemens_psirt
Update to V9.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811911/ - BehobenSIMATIC Process Historian OPC UA Serversiemens_psirt
Update to V2020 SP1 Update 1 or later version In the context of SIMATIC PCS neo, update to SIMATIC PCS neo V4.0 or later version (<https://support.industry.siemens.com/cs/ww/de/view/109814551/>); in the context of SIMATIC PCS 7, update to SIMATIC PCS 7 V9.1 SP2 or later version (<https://support.industry.siemens.com/cs/ww/en/view/109812240/>); in the context of SIMATIC WinCC, contact local support
- BehobenSIMATIC RF166C (6GT2002-0EE20)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF185C (6GT2002-0JE10)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF186C (6GT2002-0JE20)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF186CI (6GT2002-0JE50)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF188C (6GT2002-0JE40)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF188CI (6GT2002-0JE60)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF360R (6GT2801-5BA30)siemens_psirt
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811118/ - BehobenSIMATIC RF610R (6GT2811-6BC10)siemens_psirt
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF615R (6GT2811-6CC10)siemens_psirt
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF650R (6GT2811-6AB20)siemens_psirt
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF680R (6GT2811-6AA10)siemens_psirt
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF685R (6GT2811-6CA10)siemens_psirt
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 Software Controller V2siemens_psirt
Update to V21.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478528/ - BehobenSIMATIC S7-PLCSIM Advancedsiemens_psirt
Update to V5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809300/ - BehobenSIMATIC STEP 7 V17siemens_psirt
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC STEP 7 V5siemens_psirt
Update to V5.7 HF4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811212/ - BehobenSIMATIC WinCC Unified (TIA Portal)siemens_psirt
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109792171/ - BehobenSIMATIC WinCC V17siemens_psirt
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC WinCC V7.4siemens_psirt
Update to V7.4 SP1 Update 22 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826450/ - BehobenSIMATIC WinCC V7.5siemens_psirt
Update to V7.5 SP2 Update 16 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793460/ - BehobenSIMOCODE ES V17siemens_psirt
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMOTIONsiemens_psirt
Update to V5.5.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812773/ - BehobenSIMOTION SCOUT TIA V5.4siemens_psirt
Update SIMATIC STEP 7 V17 to V17 Update 5 or later version
- BehobenSINAMICS Startdrive V17siemens_psirt
Update SIMATIC STEP 7 V17 to V17 Update 5 or later version
- BehobenSINEC INSsiemens_psirt
Update to V1.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812610/ - BehobenSINEC NMSsiemens_psirt
Update to V1.0 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109813788/ - BehobenSINEMA Remote Connect Serversiemens_psirt
Update to V3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811169/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)siemens_psirt
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)siemens_psirt
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0)siemens_psirt
Update to V3.0.37 or later version
https://support.industry.siemens.com/cs/ww/en/view/109828349/ - BehobenSIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0)siemens_psirt
Update to V3.3.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817938/ - BehobenSIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)siemens_psirt
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)siemens_psirt
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0)siemens_psirt
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C AC/DC/RLY (6AG1212-1BE40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C AC/DC/RLY (6AG1214-1BG40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C AC/DC/RLY (6AG1214-1BG40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/RLY (6AG1214-1HG40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/RLY (6AG1214-1HG40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215C AC/DC/RLY (6AG1215-1BG40-2XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0)siemens_psirt
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)siemens_psirt
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)siemens_psirt
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenSIRIUS Safety ES V17 (TIA Portal)siemens_psirt
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIRIUS Soft Starter ES V17 (TIA Portal)siemens_psirt
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenTIA Administratorsiemens_psirt
Update to V1.0.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825038/ - BehobenTIA Portal Cloud V17siemens_psirt
TIA Portal Cloud V2.3 or later version updated TIA Portal to V17 Update 5 or later version
- BehobenTIM 1531 IRC (6GK7543-1MX00-0XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenTeleControl Server Basic V3siemens_psirt
Update to V3.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812231/ - Behobenphoenix_contact_psirt
This vulnerability is fixed in firmware version 8.8.6. We strongly recommend all affected FL MGUARD and TC MGUARD users to upgrade to this or a later version. PHOENIX CONTACT strongly recommends upgrading FL MGUARD DM UNLIMITED to version 1.13.0.2 or higher, which fixes this vulnerability. For FL WLAN devices the vulnerability will be fixed in the next regular release. A release date is not yet defined.
- Behobenphoenix_contact_psirt
Update to the latest LTS Firmware Release.Update to the latest LTS PLCnext Engineer Release.Please check Phoenix Contact PSIRT webpage for further Updates of this Advisory.
- BehobenIndustrial Edge - OPC UA Connectorcisa_csaf_ot
Use the Edge Management System to update to V1.7 or later version
https://www.siemens.com/industrial-edge-marketplace/ - BehobenIndustrial Edge - SIMATIC S7 Connector Appcisa_csaf_ot
Use the Edge Management System to update to V1.7 or later version
https://www.siemens.com/industrial-edge-marketplace/ - BehobenRUGGEDCOM CROSSBOW Station Access Controller (SAC)cisa_csaf_ot
Update ROX II to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenRUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenRUGGEDCOM ROX MX5000cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX MX5000REcisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1400cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1500cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1501cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1510cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1511cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1512cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1524cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX1536cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenRUGGEDCOM ROX RX5000cisa_csaf_ot
Update to V2.15.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810800/ - BehobenSCALANCE LPE9403 (6GK5998-3GS00-2AC2)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811123/ - BehobenSCALANCE M804PB (6GK5804-0AP00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M874-2 (6GK5874-2AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M874-3 (6GK5874-3AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-3 (6GK5876-3AA02-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-4 (6GK5876-4AA10-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)cisa_csaf_ot
Update to V7.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817007/ - BehobenSCALANCE SC622-2C (6GK5622-2GS00-2AC2)cisa_csaf_ot
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC632-2C (6GK5632-2GS00-2AC2)cisa_csaf_ot
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC636-2C (6GK5636-2GS00-2AC2)cisa_csaf_ot
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC642-2C (6GK5642-2GS00-2AC2)cisa_csaf_ot
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE SC646-2C (6GK5646-2GS00-2AC2)cisa_csaf_ot
Update to V2.3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810992/ - BehobenSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
Update to V8.7.1.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816886/ - BehobenSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
Update to V8.7.1.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816886/ - BehobenSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
Update to V8.7.1.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109816886/ - BehobenSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815650/ - BehobenSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2IRT (6GK5202-2BB10-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT (6GK5204-0BA00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT (6GK5204-0BA10-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X304-2FE (6GK5304-2BD00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3 (6GK5307-3BL00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3 (6GK5307-3BL10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3LD (6GK5307-3BM00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X307-3LD (6GK5307-3BM10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2 (6GK5308-2FL00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2 RD (inkl. SIPLUS variants)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LD (6GK5308-2FM00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LD (6GK5308-2FM10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH (6GK5308-2FN00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH (6GK5308-2FN10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M (6GK5308-2GG00-2AA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M (6GK5308-2GG10-2AA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M TS (6GK5308-2GG00-2CA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X308-2M TS (6GK5308-2GG10-2CA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310 (6GK5310-0FA00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310 (6GK5310-0FA10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310FE (6GK5310-0BA00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X310FE (6GK5310-0BA10-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X320-1 FE (6GK5320-1BD00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE X408-2 (6GK5408-2FD00-2AA2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208 (6GK5208-0BA00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208EEC (6GK5208-0BA00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G (6GK5208-0GA00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216 (6GK5216-0BA00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C (6GK5216-4BS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC216EEC (6GK5216-0BA00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224 (6GK5224-0BA00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204 (6GK5204-0BA00-2GF2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XF204IRT (6GK5204-0BA00-2BF2)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSCALANCE XM408-4C (6GK5408-4GP00-2AM2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM408-8C (6GK5408-8GS00-2AM2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM416-4C (6GK5416-4GS00-2AM2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XP208 (6GK5208-0HA00-2AS6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP208EEC (6GK5208-0HA00-2ES6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216 (6GK5216-0HA00-2AS6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216EEC (6GK5216-0HA00-2ES6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2)cisa_csaf_ot
Update to V4.1.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820827/ - BehobenSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (6GK5528-0AA00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSCALANCE XR552-12M (6GK5552-0AA00-2AR2)cisa_csaf_ot
Update to V6.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809635/ - BehobenSIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-1 (6GK7243-1BX30-0XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)cisa_csaf_ot
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIMATIC CP 1543-1 (6GK7543-1AX00-0XE0)cisa_csaf_ot
Update to V3.0.37 or later version
https://support.industry.siemens.com/cs/ww/en/view/109828349/ - BehobenSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)cisa_csaf_ot
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIMATIC CP 1545-1 (6GK7545-1GX00-0XE0)cisa_csaf_ot
Update to V1.1.80 or later version
https://support.industry.siemens.com/cs/ww/en/view/109994056/ - BehobenSIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0)cisa_csaf_ot
Update to V3.3.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817938/ - BehobenSIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)cisa_csaf_ot
Update to V1.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812235/ - BehobenSIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)cisa_csaf_ot
Update to V1.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812235/ - BehobenSIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773914/ - BehobenSIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773914/ - BehobenSIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)cisa_csaf_ot
Update to V21.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109759122/ - BehobenSIMATIC HMI Unified Comfort Panels familycisa_csaf_ot
Update to V18 or later version
https://support.industry.siemens.com/cs/ww/en/view/109746530/ - BehobenSIMATIC Logon V1.6cisa_csaf_ot
Update to V1.6 Upd6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805072/ - BehobenSIMATIC MV540 H (6GF3540-0GE10)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV540 S (6GF3540-0CD10)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV550 H (6GF3550-0GE10)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV550 S (6GF3550-0CD10)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV560 U (6GF3560-0LE10)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC MV560 X (6GF3560-0HE10)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811878/ - BehobenSIMATIC NET PC Software V16cisa_csaf_ot
Update to V16 Update 6 or later version
- BehobenSIMATIC NET PC Software V17cisa_csaf_ot
Update to V17 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109820674/ - BehobenSIMATIC PCS 7 TeleControlcisa_csaf_ot
Update to V9.1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826159/ - BehobenSIMATIC PCS 7 V9.1cisa_csaf_ot
Update to V9.1 SP2 UC04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - BehobenSIMATIC PCS neo (Administration Console)cisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814551/ - BehobenSIMATIC PDMcisa_csaf_ot
Update to V9.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811911/ - BehobenSIMATIC Process Historian OPC UA Servercisa_csaf_ot
Update to V2020 SP1 Update 1 or later version In the context of SIMATIC PCS neo, update to SIMATIC PCS neo V4.0 or later version (<https://support.industry.siemens.com/cs/ww/de/view/109814551/>); in the context of SIMATIC PCS 7, update to SIMATIC PCS 7 V9.1 SP2 or later version (<https://support.industry.siemens.com/cs/ww/en/view/109812240/>); in the context of SIMATIC WinCC, contact local support
- BehobenSIMATIC RF166C (6GT2002-0EE20)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF185C (6GT2002-0JE10)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF186C (6GT2002-0JE20)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF186CI (6GT2002-0JE50)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF188C (6GT2002-0JE40)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF188CI (6GT2002-0JE60)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811120/ - BehobenSIMATIC RF360R (6GT2801-5BA30)cisa_csaf_ot
Update to V2.0.1 or later version
https://support.industry.siemens.com/cs/de/en/view/109811118/ - BehobenSIMATIC RF610R (6GT2811-6BC10)cisa_csaf_ot
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF615R (6GT2811-6CC10)cisa_csaf_ot
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF650R (6GT2811-6AB20)cisa_csaf_ot
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF680R (6GT2811-6AA10)cisa_csaf_ot
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC RF685R (6GT2811-6CA10)cisa_csaf_ot
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811014/ - BehobenSIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 Software Controller V2cisa_csaf_ot
Update to V21.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478528/ - BehobenSIMATIC S7-PLCSIM Advancedcisa_csaf_ot
Update to V5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109809300/ - BehobenSIMATIC STEP 7 V17cisa_csaf_ot
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC STEP 7 V5cisa_csaf_ot
Update to V5.7 HF4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811212/ - BehobenSIMATIC WinCC Unified (TIA Portal)cisa_csaf_ot
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109792171/ - BehobenSIMATIC WinCC V17cisa_csaf_ot
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC WinCC V7.4cisa_csaf_ot
Update to V7.4 SP1 Update 22 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826450/ - BehobenSIMATIC WinCC V7.5cisa_csaf_ot
Update to V7.5 SP2 Update 16 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793460/ - BehobenSIMOCODE ES V17cisa_csaf_ot
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMOTIONcisa_csaf_ot
Update to V5.5.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812773/ - BehobenSIMOTION SCOUT TIA V5.4cisa_csaf_ot
Update SIMATIC STEP 7 V17 to V17 Update 5 or later version
- BehobenSINAMICS Startdrive V17cisa_csaf_ot
Update SIMATIC STEP 7 V17 to V17 Update 5 or later version
- BehobenSINEC INScisa_csaf_ot
Update to V1.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812610/ - BehobenSINEC NMScisa_csaf_ot
Update to V1.0 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109813788/ - BehobenSINEMA Remote Connect Servercisa_csaf_ot
Update to V3.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109811169/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)cisa_csaf_ot
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)cisa_csaf_ot
Update to V2.2.28 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817067/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0)cisa_csaf_ot
Update to V3.0.37 or later version
https://support.industry.siemens.com/cs/ww/en/view/109828349/ - BehobenSIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0)cisa_csaf_ot
Update to V3.3.11 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817938/ - BehobenSIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)cisa_csaf_ot
Update to V5.5.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817790/ - BehobenSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)cisa_csaf_ot
Update to V4.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817768/ - BehobenSIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0)cisa_csaf_ot
Update to V3.4.29 or later version
https://support.industry.siemens.com/cs/ww/en/view/109823721/ - BehobenSIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C AC/DC/RLY (6AG1212-1BE40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C AC/DC/RLY (6AG1214-1BG40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C AC/DC/RLY (6AG1214-1BG40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC (6AG1214-1AG40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/RLY (6AG1214-1HG40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214C DC/DC/RLY (6AG1214-1HG40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215C AC/DC/RLY (6AG1215-1BG40-2XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0)cisa_csaf_ot
Update to V4.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/107539610/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)cisa_csaf_ot
Update to V2.9.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)cisa_csaf_ot
Update to V3.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenSIRIUS Safety ES V17 (TIA Portal)cisa_csaf_ot
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIRIUS Soft Starter ES V17 (TIA Portal)cisa_csaf_ot
Update to V17 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenTIA Administratorcisa_csaf_ot
Update to V1.0.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825038/ - BehobenTIA Portal Cloud V17cisa_csaf_ot
TIA Portal Cloud V2.3 or later version updated TIA Portal to V17 Update 5 or later version
- BehobenTIM 1531 IRC (6GK7543-1MX00-0XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - BehobenTeleControl Server Basic V3cisa_csaf_ot
Update to V3.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812231/ - Behoben SYS600cisa_csaf_ot
For SYS600 10.x: update to at least SYS600 version 10.4.
- BehobenGateway Station (GWS)cisa_csaf_ot
Avoid directly connecting control systems to the internet
- BehobenRTU500 series CMU Firmwarecisa_csaf_ot
RTU500 series CMU Firmware version 12.0.1 � 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)
- BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIDIS Primecisa_csaf_ot
Update to V4.0.400 or later version
- BehobenBFCClientcisa_csaf_ot
Update to V2.17 or later version. Contact customer support to obtain the update
- MitigationOpenPCS 7 V8.2siemens_psirt
Restrict access to the OPC UA interface to trusted systems
- MitigationOpenPCS 7 V9.0siemens_psirt
Restrict access to the OPC UA interface to trusted systems
- MitigationOpenPCS 7 V9.1siemens_psirt
Restrict access to the OPC UA interface to trusted systems
- MitigationSIMATIC PCS 7 V9.1siemens_psirt
For the unfixed component in this version (OpenPCS 7): Restrict access to the OPC UA interface of OpenPCS 7 to trusted systems
- MitigationTIA Administratorsiemens_psirt
Disable web server within the device configuration if it is not used or limit access to the web server on a particular Ethernet/PROFINET port/interface if possible (setting is under General / Web server access).
- Mitigationphoenix_contact_psirt
To reduce the possibility of an attack, affected functionality could be deactivated or used only in a way that it is not exposed on untrusted interfaces.
- Mitigationphoenix_contact_psirt
Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:Measures to protect network-capable devices with Ethernet connection
- MitigationMELSOFT iQ AppPortal (SW1DND-IQAPL-M)cisa_csaf_ot
Install an antivirus software in the personal computer that runs this product.
- MitigationOpenPCS 7 V8.2cisa_csaf_ot
Restrict access to the OPC UA interface to trusted systems
- MitigationOpenPCS 7 V9.0cisa_csaf_ot
Restrict access to the OPC UA interface to trusted systems
- MitigationOpenPCS 7 V9.1cisa_csaf_ot
Restrict access to the OPC UA interface to trusted systems
- MitigationSIMATIC PCS 7 V9.1cisa_csaf_ot
For the unfixed component in this version (OpenPCS 7): Restrict access to the OPC UA interface of OpenPCS 7 to trusted systems
- MitigationTIA Administratorcisa_csaf_ot
Disable web server within the device configuration if it is not used or limit access to the web server on a particular Ethernet/PROFINET port/interface if possible (setting is under General / Web server access).
- MitigationCC-Link IE TSN Industrial Managed Switch (NZ2MHG-TSNT8F2 NZ2MHG-TSNT4)cisa_csaf_ot
CC-Link IE TSN Industrial Managed Switch: Mitsubishi Electric has released fixed firmware for these issues and recommends users update affected products to Version 04 or later. Users should contact Mitsubishi Electric to obtain the fixed firmware version. To update affected CC-Link IE TSN Industrial Managed Switch products log into the product with the web interface and go to [System] → [System Management] → [Firmware Upgrade] from the Function menu after obtaining the updated firmware file.
- MitigationGOT2000 compatible HMI software (GT SoftGOT2000)cisa_csaf_ot
CC-Link IE TSN Industrial Managed Switch: Mitsubishi Electric has released fixed firmware for these issues and recommends users update affected products to Version 04 or later. Users should contact Mitsubishi Electric to obtain the fixed firmware version. To update affected CC-Link IE TSN Industrial Managed Switch products log into the product with the web interface and go to [System] → [System Management] → [Firmware Upgrade] from the Function menu after obtaining the updated firmware file.
- MitigationMELSEC iQ-R Series OPC UA Server Module (RD81OPC96)cisa_csaf_ot
CC-Link IE TSN Industrial Managed Switch: Mitsubishi Electric has released fixed firmware for these issues and recommends users update affected products to Version 04 or later. Users should contact Mitsubishi Electric to obtain the fixed firmware version. To update affected CC-Link IE TSN Industrial Managed Switch products log into the product with the web interface and go to [System] → [System Management] → [Firmware Upgrade] from the Function menu after obtaining the updated firmware file.
- Mitigation SYS600cisa_csaf_ot
Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guidelines.
- MitigationRTU500 series CMU Firmwarecisa_csaf_ot
Do not allow process control systems direct connections to the internet.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- WorkaroundSICK SIM1000 FX with Firmware <= 1.5.2sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK SIM1004 with Firmware <= 1.1.0sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK SIM1012 with Firmware <= 2.0.6sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK SIM2000ST Track & Trace (2086501) with Firmware <= 1.7.0sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK SIM2000ST Track & Trace (2086502) with Firmware <= 1.13.2sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK SIM2000ST with Firmware <= 1.7.0sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK SIM4000 with Firmware <= 1.10.1sick_psirt
In the runtime context of an SIM application, the SSH access should not be required at all, it is recommended as a workaround to disable port 22 (SSH) of the corresponding Ethernet port at the SIM via App (Firewall-API).
- WorkaroundSICK MEAC300 DE all Firmware versionssick_psirt
Please make sure that you apply general security practices when operating the MEAC300 DE. The following General Security Practices and Operating Guidelines could mitigate the associated security risk.
- Kein Fix verfügbarSICK SIM1000 FX with Firmware <= 1.5.2sick_psirt
The recommended solution will be the update of the firmware to a version >= 1.6.0 (in progress, release not yet scheduled).
- Kein Fix verfügbarSICK SIM1004 with Firmware <= 1.1.0sick_psirt
The recommended solution will be the update of the firmware to a version >= 2.0.0 (in progress, release not yet scheduled).
- Kein Fix verfügbarSICK SIM1012 with Firmware <= 2.0.6sick_psirt
The recommended solution will be the update of the firmware to a version >= 2.1.0 (in progress, release not yet scheduled).
- Kein Fix verfügbarSICK SIM2000ST Track & Trace (2086501) with Firmware <= 1.7.0sick_psirt
The recommended solution will be the update of the firmware to a version >= 1.7.1 (release not yet scheduled). Please see “Workaround”.
- Kein Fix verfügbarSICK SIM2000ST Track & Trace (2086502) with Firmware <= 1.13.2sick_psirt
The recommended solution will be the update of the firmware to a version >= 1.13.3 (release not yet scheduled).
- Kein Fix verfügbarSICK SIM2000ST with Firmware <= 1.7.0sick_psirt
The recommended solution will be the update of the firmware to a version >= 1.7.1 (release not yet scheduled). Please see “Workaround”.
- Kein Fix verfügbarSICK SIM4000 with Firmware <= 1.10.1sick_psirt
The recommended solution will be the update of the firmware to a version >= 1.10.2 (release not yet scheduled). Please see “Workaround”.
- Kein Fix geplantOpenPCS 7 V8.2siemens_psirt
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V9.0siemens_psirt
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V9.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2 (6GK5204-2BB10-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2FM (6GK5204-2BB11-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2LD (6GK5204-2BC10-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2TS (6GK5204-2BB10-2CA2)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X206-1 (6GK5206-1BB10-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X206-1LD (6GK5206-1BC10-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X208 (6GK5208-0BA10-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X208PRO (6GK5208-0HA10-2AA6)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X212-2 (6GK5212-2BB00-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X212-2LD (6GK5212-2BC00-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X216 (6GK5216-0BA00-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE X224 (6GK5224-0BA00-2AA3)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE XF204 (6GK5204-0BA00-2AF2)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE XF204-2 (6GK5204-2BC00-2AF2)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE XF206-1 (6GK5206-1BC00-2AF2)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSCALANCE XF208 (6GK5208-0BA00-2AF2)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 1626 (6GK1162-6AA01)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 1628 (6GK1162-8AA00)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 443-1 OPC UA (6GK7443-1UX00-0XE0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V14siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V15siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS 7 V8.2siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS 7 V9.0siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC STEP 7 V15.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC STEP 7 V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V15.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V7.3siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMOCODE ES V15.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMOCODE ES V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMOTION SCOUT TIA V5.3siemens_psirt
Currently no fix is planned
- Kein Fix geplantSINAMICS DCC V15.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSINAMICS DCC V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantSINAMICS Startdrive V15.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSINAMICS Startdrive V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantSINAUT ST7CCsiemens_psirt
Currently no fix is planned
- Kein Fix geplantSINAUT Software ST7scsiemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIRIUS Soft Starter ES V15.1 (TIA Portal)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIRIUS Soft Starter ES V16 (TIA Portal)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSecurity Configuration Tool (SCT)siemens_psirt
Currently no fix is planned
- Kein Fix geplantTIA Portal Cloud V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V8.2cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V9.0cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V9.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2 (6GK5204-2BB10-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2FM (6GK5204-2BB11-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2LD (6GK5204-2BC10-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X204-2TS (6GK5204-2BB10-2CA2)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X206-1 (6GK5206-1BB10-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X206-1LD (6GK5206-1BC10-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X208 (6GK5208-0BA10-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X208PRO (6GK5208-0HA10-2AA6)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X212-2 (6GK5212-2BB00-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X212-2LD (6GK5212-2BC00-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X216 (6GK5216-0BA00-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE X224 (6GK5224-0BA00-2AA3)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE XF204 (6GK5204-0BA00-2AF2)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE XF204-2 (6GK5204-2BC00-2AF2)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE XF206-1 (6GK5206-1BC00-2AF2)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSCALANCE XF208 (6GK5208-0BA00-2AF2)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 1626 (6GK1162-6AA01)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 1628 (6GK1162-8AA00)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC CP 443-1 OPC UA (6GK7443-1UX00-0XE0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V14cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V15cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS 7 V8.2cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS 7 V9.0cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC STEP 7 V15.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC STEP 7 V16cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V15.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V16cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V7.3cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMOCODE ES V15.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMOCODE ES V16cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMOTION SCOUT TIA V5.3cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSINAMICS DCC V15.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSINAMICS DCC V16cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSINAMICS Startdrive V15.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSINAMICS Startdrive V16cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSINAUT ST7CCcisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSINAUT Software ST7sccisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIRIUS Soft Starter ES V15.1 (TIA Portal)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIRIUS Soft Starter ES V16 (TIA Portal)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSecurity Configuration Tool (SCT)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantTIA Portal Cloud V16cisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5–7.5
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
Exploits (6)
Öffentlicher Proof-of-Concept- und Exploit-Code.
- 0xUhaw/CVE-2022-0778Proof of concept for CVE-2022-0778 in P12 and PEM formatPoC · poc_in_github
- jeongjunsoo/CVE-2022-0778jeongjunsoo/CVE-2022-0778PoC · poc_in_github
- jkakavas/CVE-2022-0778-POCjkakavas/CVE-2022-0778-POCPoC · poc_in_github
- yywing/cve-2022-0778yywing/cve-2022-0778PoC · poc_in_github
betroffene Produkte (1,501)
Betroffene Produkte und Versionsbereiche.
Advisories (43)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0239Kwetsbaarheden verholpen in Solarwinds PlatformNL2024-06-07csaf · ncsc_nlNL
Solarwinds heeft kwetsbaarheden verholpen in Solarwinds Platform.
- NCSC-2024-0333Kwetsbaarheden verholpen in SAP productenNL2024-08-13csaf · ncsc_nlNL
SAP heeft kwetsbaarheden verholpen in diverse producten als SAP Business Objects, SAP HANA, Netweaver en Document Builder.
- NCSC-2026-0112Kwetsbaarheden verholpen in Siemens productenNL2026-04-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten zoals Analytics Toolkit, Ruggedcom, Industrial Edge Management Pro, SIDIS en TPM.
- SCA-2022-0012OpenSSL vulnerability affects multiple SICK SIMs2022-08-08csaf · sick_psirtDE
In March 2022, the OpenSSL development team disclosed a denial of service in versions "3.0.0," "3.0.1," "1.1.1"-"1.1.1m" and "1.0.2-1.0.2zc" of the OpenSSL library. Exploiting this vulnerability allows remote, unauthenticated attackers to cause an infinite loop. It is possible to trigger the infinite loop by creating a certificate that has invalid explicit curve parameters or when parsing created private keys, as they may contain explicit elliptic curve parameters. It may be possible to put the SIMs in a non-responsive state since 100% of the CPU resource is consumed by the infinite loop calculation. The listed SICK SIM products are currently operated with an OpenSSL version that is vulnerable to CVE-2022-0778. With that it could be possible to exploit the mentioned vulnerability if the SIM devices are connected to a network with untrusted devices. In that case an untrusted client may send a manipulated SSH-certificate to the SIM, which exploits the vulnerability in the OpenSSL library as described above when it comes to the certificate validation by the SIM product. Evaluation is undergoing.
- SCA-2025-0001Multiple vulnerabilities in SICK MEAC3002025-02-14csaf · sick_psirtDE
SICK has identified vulnerabilities in MEAC300. These vulnerabilities, related to the OpenSSL library and specific device functionalities, could potentially allow remote, unauthenticated attackers to: 1) Cause a denial of service: Triggering an infinite loop that consumes CPU resources, rendering the device unresponsive (CVE-2022-0778). This impacts MEAC300 DE devices running vulnerable OpenSSL versions when processing manipulated SSH certificates. 2) Compromise the MEAC300: Exploit vulnerabilities accessible via Ethernet to potentially impact the availability, integrity, and confidentiality of the device. SICK recommends ensuring that affected products operate within secure network environments to mitigate these risks.
- SSA-019200SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.02026-04-14csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.
- SSA-028723SSA-028723: Multiple OpenSSL Vulnerabilities in BFCClient Before V2.172025-08-12csaf · siemens_psirtDE
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
- SSA-108696SSA-108696: Multiple Vulnerabilities in SIDIS Prime before V4.0.4002024-02-13csaf · siemens_psirtDE
SIDIS Prime before V4.0.400 is affected by multiple vulnerabilities in the components OPC UA and OpenSSL, that could allow an unauthenticated attacker with access to the network where SIDIS Prime is installed to reuse OPC UA client credentials, create a denial of service condition of the SIDIS Prime OPC UA client, or create a denial of service condition of the SIDIS Prime TLS service. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-712929SSA-712929: Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products2022-06-14csaf · siemens_psirtDE
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. [0] https://www.openssl.org/news/secadv/20220315.txt
- VDE-2022-013PHOENIX CONTACT: Multiple products affected by possible infinite loop within OpenSSL library2022-04-12csaf · phoenix_contact_psirtDE
FL MGUARD and TC MGUARD devices are affected by a possible infinite loop within a OpenSSL library method for parsing elliptic curve parameters. This method is used on parsing cryptographic certificates that contain elliptic curve public keys in compressed form, which may occur on: Parsing client certificates for HTTPS administrative login Parsing client certificates for SSH administrative login Parsing peer certificates for IPsec VPN connections Parsing certificates of external servers, including: OpenVPN server Configuration pull server Update server Attackers could try to exploit the vulnerability from remote. For the mGuard Device Manager only the mdm Installer for Windows is affected. UPDATE A: Added FL MGUARD 1102 and FL MGUARD 1105: On FL MGUARD 1102 and FL MGUARD 1105 with mGuardNT 1.5.2 and older, the device can be affected through an adapted certificate. This can occur on connection with a remote logging server, configured for certificate authentication, or an remote authentication server at certificate based authentication.
- VDE-2022-046PHOENIX CONTACT: Multiple Linux component vulnerabilities in PLCnext Firmware2022-11-10csaf · phoenix_contact_psirtDE
UPDATE A: Two devices (ENERGY AXC PU, SMARTRTU AXC SG) added (24.11.2022) Update for PLCnext Firmware containing fixes for recent vulnerability findings in Linux components and security enhancements. PLCnext Control AXC F x152 is certified according to IEC 62443-4-1 and IEC 62443-4-2. This certification requires that all third-party components used in the firmware are regularly checked for known vulnerabilities.
- WID-SEC-W-2022-0065OpenSSL: Schwachstelle ermöglicht Denial of ServiceDeutsch2022-03-15csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2022-0169Oracle MySQL: Mehrere SchwachstellenDeutsch2022-04-19csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2022-0200Oracle Java SE und OpenJDK: Mehrere SchwachstellenDeutsch2022-04-19csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Oracle Java SE und OpenJDK ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2022-0302Xerox FreeFlow Print Server: Mehrere Schwachstellen ermöglichen Ausführen von beliebigem Programmcode mit AdministratorrechtenDeutsch2022-06-14csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um beliebigen Programmcode auszuführen, einen Cross-Site-Scripting-Angriff durchzuführen, Informationen offenzulegen, einen Denial-of-Service-Zustand zu verursachen oder Dateien zu manipulieren.
- WID-SEC-W-2022-0432Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2022-06-21csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität zu gefährden.
- WID-SEC-W-2022-0515IBM Spectrum Protect: Mehrere SchwachstellenDeutsch2022-06-29csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in IBM Spectrum Protect ausnutzen, um einen Denial-of-Service-Zustand herbeizuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, beliebigen Code auszuführen, seine Rechte zu erweitern oder beliebigen Code mit Root-Rechten auszuführen.
- WID-SEC-W-2022-0551Kyocera Drucker: Mehrere SchwachstellenDeutsch2022-07-03csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Kyocera Druckern ausnutzen, um beliebigen Programmcode auszuführen, einen Cross-Site-Scritping Angriff durchzuführen und einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2022-1057Apple macOS: Mehrere SchwachstellenDeutsch2022-05-16csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in Apple macOS ausnutzen, um seine Privilegien zu erweitern, beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, einen Denial-of-Service-Zustand herbeizuführen, vertrauliche Informationen offenzulegen und im schlimmsten Fall das System zu kompromittieren.
- WID-SEC-W-2022-1335Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2022-09-07csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2023-1969HPE Fabric OS: Mehrere Schwachstellen ermöglichen PrivilegieneskalationDeutsch2023-08-06csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in HPE Fabric OS für HPE Fibre Channel und SAN Switches ausnutzen, um seine Privilegien zu erhöhen, Informationen offenzulegen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1186IBM DB2 REST: Mehrere SchwachstellenDeutsch2024-05-20csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in IBM DB2 REST ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen oder einen Denial-of-Service-Zustand zu verursachen.
- WID-SEC-W-2024-2086SAP Patchday September 2024Deutsch2024-09-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in SAP Software ausnutzen, um seine Privilegien zu erhöhen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand zu erzeugen oder einen Cross-Site-Scripting-Angriff durchzuführen.
- WID-SEC-W-2026-0180Dell Data Protection Advisor: Mehrere SchwachstellenDeutsch2026-01-20csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell Data Protection Advisor ausnutzen, um beliebigen Code auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Sicherheitsmaßnahmen zu umgehen und nicht näher spezifizierte Angriffe zu starten.
- GHSA-x3mh-jvjw-3xwxopenssl-src's infinite loop in `BN_mod_sqrt()` reachable when parsing certificates2022-03-16ghsa · osvUS
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
- ICSA-22-132-02Mitsubishi Electric MELSOFT iQ AppPortal2022-05-12icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in a denial-of-service condition, malicious program execution, information disclosure, information tampering, or authentication bypass.
- ICSA-22-167-14Siemens OpenSSL Affected Industrial Products2022-06-14icsa · cisa_csaf_otUS
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. [0] https://www.openssl.org/news/secadv/20220315.txt
- ICSA-22-221-01Mitsubishi Electric Multiple Factory Automation Products (Update B)2022-08-30icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could create a denial-of-service condition or enable arbitrary code execution.
- ICSA-22-272-02Hitachi Energy MicroSCADA Pro X SYS6002022-09-29icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could cause the affected modules in the product to stop working.
- ICSA-23-059-01Hitachi Energy Gateway Station2023-03-06icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could cause affected modules to stop working.
- ICSA-23-143-02Hitachi Energy's RTU500 Series Product (UPDATE B)2023-05-05icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to crash the device being accessed or cause a denial-of-service condition.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-046-02Siemens SIDIS Prime2024-02-13icsa · cisa_csaf_otUS
SIDIS Prime before V4.0.400 is affected by multiple vulnerabilities in the components OPC UA and OpenSSL, that could allow an unauthenticated attacker with access to the network where SIDIS Prime is installed to reuse OPC UA client credentials, create a denial of service condition of the SIDIS Prime OPC UA client, or create a denial of service condition of the SIDIS Prime TLS service. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version.
- ICSA-25-226-21Siemens BFCClient2025-08-12icsa · cisa_csaf_otUS
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
- ICSA-26-111-07Siemens SCALANCE2026-04-14icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.
- BIT-mariadb-2022-0778Infinite loop in BN_mod_sqrt() reachable when parsing certificates2024-03-06vendor · osvUS
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
- BIT-mariadb-min-2022-0778Infinite loop in BN_mod_sqrt() reachable when parsing certificates2025-06-10vendor · osvUS
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
- BIT-mysql-client-2022-0778Infinite loop in BN_mod_sqrt() reachable when parsing certificates2024-03-06vendor · osvUS
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
- BIT-node-2022-0778Infinite loop in BN_mod_sqrt() reachable when parsing certificates2024-03-06vendor · osvUS
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
- BIT-node-min-2022-0778Infinite loop in BN_mod_sqrt() reachable when parsing certificates2024-12-16vendor · osvUS
The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
- RUSTSEC-2022-0014Infinite loop in `BN_mod_sqrt()` reachable when parsing certificates2022-03-15vendor · osvUS
The `BN_mod_sqrt()` function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the `BN_mod_sqrt()` where the attacker can control the parameter values are vulnerable to this DoS issue.
auch bekannt als (11)
Weitere Namen und Kennungen dieser Entität.
- CNNVD-202203-1394cnnvd
- EUVD-2022-1575enisa_euvd
- BDU:2022-01315fstec_bdu
- GHSA-x3mh-jvjw-3xwxenisa_euvd
- BIT-mariadb-2022-0778osv
- BIT-mariadb-min-2022-0778osv
- BIT-mysql-client-2022-0778osv
- BIT-node-2022-0778osv
- BIT-node-min-2022-0778osv
- GHSA-x3mh-jvjw-3xwxosv
- RUSTSEC-2022-0014osv
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (179)
Externe Belege — Patches, Meldungen, Analysen.
- http://seclists.org/fulldisclosure/2022/May/33cnnvd
- http://seclists.org/fulldisclosure/2022/May/35cnnvd
- http://seclists.org/fulldisclosure/2022/May/38cnnvd
- https://access.redhat.com/security/cve/cve-2022-0778cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-0778/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=3118eb64934499d93db3230748a452351d1d9a65cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=380085481c64de749a6dd25cdf0bcf4360b30f83cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan