CVE-2021-46304
highPriorität · verfolgen · 30EPSS 0.007 · 52. PerzentilDEEURUUSEPSS · bewertet 2026-10-24
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationCP-8000 MASTER MODULE WITH I/O -25/+70°Csiemens_psirt
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8000 MASTER MODULE WITH I/O -40/+70°Csiemens_psirt
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8021 MASTER MODULEsiemens_psirt
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8022 MASTER MODULE WITH GPRSsiemens_psirt
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8000 MASTER MODULE WITH I/O -25/+70°Ccisa_csaf_ot
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8000 MASTER MODULE WITH I/O -40/+70°Ccisa_csaf_ot
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8021 MASTER MODULEcisa_csaf_ot
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- MitigationCP-8022 MASTER MODULE WITH GPRScisa_csaf_ot
Operate the affected web server module only when required and consider the security instructions provided in the updated manual (see also Additional Information chapter)
- Kein Fix geplantCP-8000 MASTER MODULE WITH I/O -25/+70°Csiemens_psirt
Currently no fix is planned
- Kein Fix geplantCP-8000 MASTER MODULE WITH I/O -40/+70°Csiemens_psirt
Currently no fix is planned
- Kein Fix geplantCP-8021 MASTER MODULEsiemens_psirt
Currently no fix is planned
- Kein Fix geplantCP-8022 MASTER MODULE WITH GPRSsiemens_psirt
Currently no fix is planned
- Kein Fix geplantCP-8000 MASTER MODULE WITH I/O -25/+70°Ccisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantCP-8000 MASTER MODULE WITH I/O -40/+70°Ccisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantCP-8021 MASTER MODULEcisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantCP-8022 MASTER MODULE WITH GPRScisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.3–7.5
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (23)
Betroffene Produkte und Versionsbereiche.
- siemens cp-8000 master module with i/o -25/+70 firmwarealle VersionennvdUScpe:2.3:o:siemens:cp-8000_master_module_with_i\/o_-25\/\+70_firmware:*:*:*:*:*:*:*:*
- siemens cp-8000 master module with i/o -40/+70 firmwarealle VersionennvdUScpe:2.3:o:siemens:cp-8000_master_module_with_i\/o_-40\/\+70_firmware:*:*:*:*:*:*:*:*
- siemens cp-8021 master module firmwarealle VersionennvdUScpe:2.3:o:siemens:cp-8021_master_module_firmware:*:*:*:*:*:*:*:*
- siemens cp-8022 master module with gprs firmwarealle VersionennvdUScpe:2.3:o:siemens:cp-8022_master_module_with_gprs_firmware:*:*:*:*:*:*:*:*
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-185638SSA-185638: Authentication Bypass Vulnerability in SICAM A8000 Web Server Module2022-08-09csaf · siemens_psirtDE
A vulnerability was identified in the web server module used in the SICAM A8000 CP-8000, CP-8021 and CP-8022 devices' protocol firmwares. - AGPMT0 (AGP Master) - DNPiT1 (DNP3 TCP/IP Server) - DNPiT2 (DNP3 TCP/IP Client) - DNPMT0 (DNP3 Master seriell) - DNPST0 (DNP3 Slave seriell) - ET83 (61850 Ed.1) - ET85 (61850 Ed.2) - MBCiT0 (MODBUS TCP/IP Client) - MBSiT0 (MODBUS TCP/IP Server) - MODMT2 (MODBUS Master seriell) - OPUPT0 (OPCUA Pub/Sub) - OPUPT1 (Mindconnect) The vulnerability could allow unauthenticated access to the web interface of the affected web server module. The module is used for diagnostic purposes as well as commissioning and has to be activated manually within the protocol firmwares. For this reason the protocol firmwares are secure by default. Siemens updated the manual to make the situation transparent and raise awareness for operators. Siemens recommends countermeasures for products where updates are not, or not yet available.
- ICSA-22-223-05Siemens SICAM A8000 Web Server Module2022-08-09icsa · cisa_csaf_otUS
A vulnerability was identified in the web server module used in the SICAM A8000 CP-8000, CP-8021 and CP-8022 devices' protocol firmwares. - AGPMT0 (AGP Master) - DNPiT1 (DNP3 TCP/IP Server) - DNPiT2 (DNP3 TCP/IP Client) - DNPMT0 (DNP3 Master seriell) - DNPST0 (DNP3 Slave seriell) - ET83 (61850 Ed.1) - ET85 (61850 Ed.2) - MBCiT0 (MODBUS TCP/IP Client) - MBSiT0 (MODBUS TCP/IP Server) - MODMT2 (MODBUS Master seriell) - OPUPT0 (OPCUA Pub/Sub) - OPUPT1 (Mindconnect) The vulnerability could allow unauthenticated access to the web interface of the affected web server module. The module is used for diagnostic purposes as well as commissioning and has to be activated manually within the protocol firmwares. For this reason the protocol firmwares are secure by default. Siemens updated the manual to make the situation transparent and raise awareness for operators. Siemens recommends countermeasures for products where updates are not, or not yet available.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2021-46304/cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-22-223-05cnnvd
- https://www.auscert.org.au/bulletins/ESB-2022.4034cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdfVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.