A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 6.6–9.1

v2.09highAV:N/AC:L/Au:S/C:C/I:C/A:Cprimary · NVD / NIST USAusnutzbarkeit 8 · Auswirkung 10
v3.17.2highCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.2 · Auswirkung 5.9
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.2highAV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16.6mediumCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (16)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-496292SSA-496292: Remote Code Execution Vulnerability in POWER METER SICAM Q1002021-12-14csaf · siemens_psirtDE

    POWER METER SICAM Q100 contains a vulnerability that could allow an attacker to remotely execute code. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-21-350-07Siemens POWER METER SICAM Q1002021-12-14icsa · cisa_csaf_otUS

    POWER METER SICAM Q100 contains a vulnerability that could allow an attacker to remotely execute code. Siemens has released updates for the affected products and recommends to update to the latest versions.