CVE-2021-43550
lowPriorität · verfolgen · 26OT-Risiko · erhöhtEPSS 0.002 · 14. PerzentilEUUSEPSS · bewertet 2026-10-27
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenEfficia CM Seriescisa_csaf_ot
Philips released a remediation for CVE-2021-43548 in Q3 2021 in PIC iX C.03.06. Philips plans to remediate CVE-2021-43552 and CVE-2021-43550 by end of Q2 of 2023. Users should operate all Philips deployed and supported products within Philips authorized specifications, including Philips approved software, software configuration, system services, and security configuration.
- BehobenPatient Information Center iX (PIC iX)cisa_csaf_ot
Philips released a remediation for CVE-2021-43548 in Q3 2021 in PIC iX C.03.06. Philips plans to remediate CVE-2021-43552 and CVE-2021-43550 by end of Q2 of 2023. Users should operate all Philips deployed and supported products within Philips authorized specifications, including Philips approved software, software configuration, system services, and security configuration.
- MitigationEfficia CM Seriescisa_csaf_ot
By default, patient information is not included in archives. When exporting archives that contain patient information, users should store information securely with strong access controls.
- MitigationPatient Information Center iX (PIC iX)cisa_csaf_ot
By default, patient information is not included in archives. When exporting archives that contain patient information, users should store information securely with strong access controls.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 3.3–6.5
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (12)
Betroffene Produkte und Versionsbereiche.
- philips patient information center ix= c.02nvdUScpe:2.3:a:philips:patient_information_center_ix:*:*:*:*:*:*:*:*
- philips patient information center ix= c.03nvdUScpe:2.3:a:philips:patient_information_center_ix:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSMA-21-322-02Philips Patient Information Center iX (PIC iX) and Efficia CM Series2021-11-18icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities may allow an attacker unauthorized access to data (including patient data) and create a denial of service resulting in temporary interruption of viewing physiological data at the central station. Exploitation does not enable modification or change to point-of-care devices.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (7)
Externe Belege — Patches, Meldungen, Analysen.
- https://nvd.nist.gov/vuln/detail/CVE-2021-43550cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsma-21-322-02cnnvd
- https://www.auscert.org.au/bulletins/ESB-2021.3947cnnvd
- https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2021111904cnnvd
- https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02enisa_euvd
- https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02Third Party AdvisoryUS Government Resourcenvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan