CVE-2021-41838
highPriorität · verfolgen · 33EPSS 0.003 · 23. PerzentilDEEUUSEPSS · bewertet 2026-10-27
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenRUGGEDCOM APE1808 - BIOSsiemens_psirt
Update to V1.0.202N or later version
https://support.industry.siemens.com/cs/ww/en/view/109814796/ - BehobenSIMATIC Field PG M5siemens_psirt
Update to V22.01.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC Field PG M6siemens_psirt
Update to V26.01.13 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC127Esiemens_psirt
Update to V27.01.09 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC227Gsiemens_psirt
Update to V28.01.04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC277Gsiemens_psirt
Update to V28.01.04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC327Gsiemens_psirt
Update to V28.01.04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC377Gsiemens_psirt
Update to V28.01.04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC427Esiemens_psirt
Update to V21.01.17 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC477Esiemens_psirt
Update to V21.01.17 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC477E Prosiemens_psirt
Update to V21.01.17 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC627Esiemens_psirt
Update to V25.02.12 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC647Esiemens_psirt
Update to V25.02.12 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC677Esiemens_psirt
Update to V25.02.12 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC847Esiemens_psirt
Update to V25.02.12 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC ITP1000siemens_psirt
Update to V23.01.10 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIMATIC IPC277G PROsiemens_psirt
Update to V28.01.04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - BehobenSIPLUS IPC427Esiemens_psirt
Update to V21.01.17 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763408/ - MitigationRUGGEDCOM APE1808 - BIOSsiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC Field PG M5siemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC Field PG M6siemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC127Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC227Gsiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC277Gsiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC327Gsiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC377Gsiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC427Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC477Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC477E Prosiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC627Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC647Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC677Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC847Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC ITP1000siemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIMATIC IPC277G PROsiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
- MitigationSIPLUS IPC427Esiemens_psirt
As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (56)
Betroffene Produkte und Versionsbereiche.
- siemens simatic field pg m5 firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*
- siemens simatic field pg m6 firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc127e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc227g firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc277g firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc327g firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc377g firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc427e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc477e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc627e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc647e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc677e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*
- siemens simatic ipc847e firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*
- siemens simatic itp1000 firmwarealle VersionennvdUScpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-306654SSA-306654: Insyde BIOS Vulnerabilities in Siemens Industrial Products2022-02-22csaf · siemens_psirtDE
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (18)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdfcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2021-41838cnnvd
- https://security.netapp.com/advisory/ntap-20220222-0001/cnnvd
- https://support.lenovo.com/us/en/product_security/LEN-73436cnnvd
- https://vigilance.fr/vulnerability/Independent-BIOS-Developers-multiple-vulnerabilities-via-UEFI-37438cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2022020315cnnvd
- https://www.insyde.com/security-pledgecnnvd
- https://www.insyde.com/security-pledge/SA-2022023cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan