CVE-2021-37180

mediumPriorität · verfolgen · 31EPSS 0.014 · 72. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.38% (72nd) EPSS
CVSS 6.8 · medium
Is it mine?
5 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–7.8

v2.06.8mediumAV:N/AC:M/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 6.4
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.07.8highCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:Csecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (5)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-818688SSA-818688: Multiple Vulnerabilities in Solid Edge before SE2021MP72021-08-10csaf · siemens_psirtDE

    Siemens has released a new version for Solid Edge that fixes three vulnerabilities - an XML external entity (XXE) injection, and two file parsing issues which could be triggered when the application reads OBJ files. If a user is tricked to opening a malicious file using the affected application this could lead the application to crash, or potentially arbitrary code execution and data extraction on the target host system. Siemens recommends to update to the latest version and to limit opening of files from unknown sources in the affected products.

  • ICSA-21-222-08ICSA-21-222-08_Siemens Solid Edge2021-08-10icsa · cisa_csaf_otUS

    Xina1i, working with Trend Micro 's Zero Day Initiative, and Michael Heinzl reported these vulnerabilities to CISA.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2021-08-10geändert 2026-06-17
08

Referenzen (9)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan