CVE-2021-35942
mediumPriorität · verfolgen · 37EPSS 0.028 · 86. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
The wordexp function in the GNU C Library (aka glibc) through 2.33 may crash or read arbitrary memory in parse_param (in posix/wordexp.c) when called with an untrusted, crafted pattern, potentially resulting in a denial of service or disclosure of information. This occurs because atoi was used but strtoul should have been used to ensure correct calculations.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 TM MFP - BIOSsiemens_psirt
Update to V1.3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109945851/ - Behobenphoenix_contact_psirt
**Update to Firmware Release 2022.0.3 LTS or higher:** - AXC F 2152 (2404267) [Download](http://www.phoenixcontact.net/qr/2404267/firmware) - AXC F 1152 (1151412) [Download](http://www.phoenixcontact.net/qr/1151412/firmware) - AXC F 3152 (1069208) Not yet released **Update to PLCnext Engineer Release 2022.0.1 LTS or higher.**
- BehobenSIMATIC S7-1500 TM MFP - BIOScisa_csaf_ot
Update to V1.3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109945851/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - Mitigationphoenix_contact_psirt
Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note: Measures to protect network-capable devices with Ethernet connection
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- WorkaroundSIMATIC S7-1500 TM MFP - BIOSsiemens_psirt
Only build and run applications from trusted sources
- WorkaroundSIMATIC S7-1500 TM MFP - BIOScisa_csaf_ot
Only build and run applications from trusted sources
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 6.4–9.1
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (50)
Betroffene Produkte und Versionsbereiche.
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
Advisories (7)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-831302SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.02023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.
- VDE-2022-010PHOENIX CONTACT: Multiple Linux component vulnerabilities fixed in latest AXC F x152 LTS release2022-04-12csaf · phoenix_contact_psirtDE
PLCnext Control AXC F x152 is certified according to IEC 62443-4-1 and IEC 62443-4-2. This certification requires that all third-party components used in the firmware are regularly checked for known vulnerabilities. Firmware components in version 2021.06 had already been updated. For the 2022.0 LTS version more firmware components have been updated implicitly fixing the vulnerabilities listed. The vulnerabilities listed above have not been individually verified in terms of actual impact and/or limitations in combination with the affected products listed. The current LTS release 2022.0 LTS contains updates of integrated third-party libraries, SDKs and other third-party software to address these issues nevertheless. UPDATE A (April 4th, 2022): Added RFC 4072 (Art. No. 1051328) and fixed affected version of AXC F 3152
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2024-1186IBM DB2 REST: Mehrere SchwachstellenDeutsch2024-05-20csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in IBM DB2 REST ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen oder einen Denial-of-Service-Zustand zu verursachen.
- ICSA-23-166-10Siemens SIMATIC S7-1500 TM MFP BIOS2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (53)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2021-35942cnnvd
- https://lists.debian.org/debian-lts-announce/2022/10/msg00021.htmlcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2021-35942cnnvd
- https://packetstormsecurity.com/files/164863/Red-Hat-Security-Advisory-2021-4358-03.htmlcnnvd
- https://packetstormsecurity.com/files/166183/Ubuntu-Security-Notice-USN-5310-1.htmlcnnvd
- https://packetstormsecurity.com/files/168074/Gentoo-Linux-Security-Advisory-202208-24.htmlcnnvd
- https://packetstormsecurity.com/files/169526/Ubuntu-Security-Notice-USN-5699-1.htmlcnnvd
- https://security.gentoo.org/glsa/202208-24cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.