CVE-2021-34315

mediumPriorität · verfolgen · 32EPSS 0.017 · 77. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.66% (77th) EPSS
CVSS 6.8 · medium
Is it mine?
10 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13356)

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–7.8

v2.06.8mediumAV:N/AC:M/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 6.4
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.07.8highCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (10)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-483182SSA-483182: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.22021-07-13csaf · siemens_psirtDE

    Siemens has released version V13.2 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (GIF, TIFF, BMP, J2K, JT, SGI, PDF, PCT, PCX, PAR and ASM ). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution on the target host system. Siemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.

  • ICSA-21-194-15ICSA-21-194-15_Siemens JT2Go and Teamcenter Visualization2021-07-13icsa · cisa_csaf_otUS

    Brian Gorenc and Mat Powell of Trend Micro Zero Day Initiative; garmin and xina1i at SecZone; and Tran Van Khang - khangkito (VinCSS) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2021-07-13geändert 2026-06-17