A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.07.2highAV:L/AC:L/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 10
v3.18.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 2 · Auswirkung 6
v3.17.3highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:L/E:U/RL:O/RC:Csecondary · CISA US
v3.17.3highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:L/E:U/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.18.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (26)

Betroffene Produkte und Versionsbereiche.

20 von 26 angezeigt
05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-661034SSA-661034: Incorrect Permission Assignment in Multiple SIMATIC Software Products2021-07-13csaf · siemens_psirtDE

    Multiple SIMATIC software products are affected by a vulnerability that could allow an attacker to change the content of certain metafiles and subsequently manipulate parameters or behaviour of devices configured by the affected software products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.

  • ICSA-21-194-06Siemens SIMATIC Software Products (Update B)2021-07-13icsa · cisa_csaf_otUS

    Multiple SIMATIC software products are affected by a vulnerability that could allow an attacker to change the content of certain metafiles and subsequently manipulate parameters or behaviour of devices configured by the affected software products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2021-07-13geändert 2026-06-17
08

Referenzen (7)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan