CVE-2021-31340
mediumPriorität · verfolgen · 30EPSS 0.010 · 62. PerzentilDEEUUSEPSS · bewertet 2026-10-28
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC RF166Csiemens_psirt
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF185Csiemens_psirt
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF186Csiemens_psirt
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF186CIsiemens_psirt
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF188Csiemens_psirt
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF188CIsiemens_psirt
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF360Rsiemens_psirt
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808759 - BehobenSIMATIC Reader RF610R CMIITsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF610R ETSIsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF610R FCCsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF615R CMIITsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF615R ETSIsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF615R FCCsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R ARIBsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R CMIITsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R ETSIsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R FCCsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R ARIBsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R CMIITsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R ETSIsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R FCCsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R ARIBsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R CMIITsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R ETSIsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R FCCsiemens_psirt
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC RF166Ccisa_csaf_ot
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF185Ccisa_csaf_ot
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF186Ccisa_csaf_ot
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF186CIcisa_csaf_ot
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF188Ccisa_csaf_ot
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF188CIcisa_csaf_ot
Update to V1.3.2
https://support.industry.siemens.com/cs/ww/en/view/109768507 - BehobenSIMATIC RF360Rcisa_csaf_ot
Update to V2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808759 - BehobenSIMATIC Reader RF610R CMIITcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF610R ETSIcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF610R FCCcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF615R CMIITcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF615R ETSIcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF615R FCCcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R ARIBcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R CMIITcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R ETSIcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF650R FCCcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R ARIBcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R CMIITcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R ETSIcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF680R FCCcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R ARIBcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R CMIITcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R ETSIcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - BehobenSIMATIC Reader RF685R FCCcisa_csaf_ot
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808361 - MitigationSIMATIC RF166Csiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF185Csiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF186Csiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF186CIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF188Csiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF188CIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF360Rsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF610R CMIITsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF610R ETSIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF610R FCCsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF615R CMIITsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF615R ETSIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF615R FCCsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R ARIBsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R CMIITsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R ETSIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R FCCsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R ARIBsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R CMIITsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R ETSIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R FCCsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R ARIBsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R CMIITsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R ETSIsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R FCCsiemens_psirt
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF166Ccisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF185Ccisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF186Ccisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF186CIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF188Ccisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF188CIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC RF360Rcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF610R CMIITcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF610R ETSIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF610R FCCcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF615R CMIITcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF615R ETSIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF615R FCCcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R ARIBcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R CMIITcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R ETSIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF650R FCCcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R ARIBcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R CMIITcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R ETSIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF680R FCCcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R ARIBcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R CMIITcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R ETSIcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
- MitigationSIMATIC Reader RF685R FCCcisa_csaf_ot
Deactivate the OPC-UA feature of affected devices
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5–7.5
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (131)
Betroffene Produkte und Versionsbereiche.
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-787292SSA-787292: Denial of Service Vulnerability in SIMATIC RFID Readers2021-06-08csaf · siemens_psirtDE
The latest updates for SIMATIC RF products fix a vulnerability that could allow an unauthorized attacker to crash the OPC UA service of the affected devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-21-159-13Siemens SIMATIC RFID (Update B)2021-06-08icsa · cisa_csaf_otUS
The latest updates for SIMATIC RF products fix a vulnerability that could allow an unauthorized attacker to crash the OPC UA service of the affected devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdfcnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-159-13cnnvd
- https://vigilance.fr/vulnerability/SIMATIC-RFID-Readers-overload-via-Incoming-Connections-35642cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2021061004cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdfMitigationPatchVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.