CVE-2021-27383
mediumPriorität · verfolgen · 31EPSS 0.018 · 78. PerzentilDEEUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC WinCC Runtime Advanced V15siemens_psirt
Update to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC WinCC Runtime Advanced V16siemens_psirt
Update to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109776018/ - BehobenSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC WinCC Runtime Advanced V15cisa_csaf_ot
Update to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC WinCC Runtime Advanced V16cisa_csaf_ot
Update to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109776018/ - MitigationSINAMICS GH150siemens_psirt
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version
- MitigationSINAMICS GL150 (with option X30)siemens_psirt
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version
- MitigationSINAMICS GM150 (with option X30)siemens_psirt
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version
- MitigationSINAMICS SH150siemens_psirt
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version
- MitigationSINAMICS SL150siemens_psirt
As only SIMATIC HMI image versions < V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version
- MitigationSINAMICS SM120siemens_psirt
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version
- MitigationSINAMICS SM150siemens_psirt
As only SIMATIC HMI image versions < V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version
- MitigationSINAMICS SM150isiemens_psirt
As only SIMATIC HMI image versions < V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version
- MitigationSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V15siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V16siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSINAMICS GH150cisa_csaf_ot
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GH150 to V16 Update 4 or later version
- MitigationSINAMICS GL150 (with option X30)cisa_csaf_ot
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GL150 (with option X30) to V16 Update 4 or later version
- MitigationSINAMICS GM150 (with option X30)cisa_csaf_ot
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS GM150 (with option X30) to V16 Update 4 or later version
- MitigationSINAMICS SH150cisa_csaf_ot
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SH150 to V16 Update 4 or later version
- MitigationSINAMICS SL150cisa_csaf_ot
As only SIMATIC HMI image versions < V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SL150 to V15 SP1 Update 6 or later version
- MitigationSINAMICS SM120cisa_csaf_ot
As only SIMATIC HMI image versions < V16 Update 4 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM120 to V16 Update 4 or later version
- MitigationSINAMICS SM150cisa_csaf_ot
As only SIMATIC HMI image versions < V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150 to V15 SP1 Update 6 or later version
- MitigationSINAMICS SM150icisa_csaf_ot
As only SIMATIC HMI image versions < V15 SP1 Update 6 are affected, please update the HMI Panel image as included in your installation of SINAMICS SM150i to V15 SP1 Update 6 or later version
- MitigationSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V15cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V16cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- Kein Fix verfügbarSINAMICS GH150siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS GL150 (with option X30)siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS GM150 (with option X30)siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SH150siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SL150siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SM120siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SM150siemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SM150isiemens_psirt
Currently no remediation is available
- Kein Fix verfügbarSINAMICS GH150cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS GL150 (with option X30)cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS GM150 (with option X30)cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SH150cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SL150cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SM120cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SM150cisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarSINAMICS SM150icisa_csaf_ot
Currently no remediation is available
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5–7.5
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (112)
Betroffene Produkte und Versionsbereiche.
Advisories (4)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-286838SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products2021-05-11csaf · siemens_psirtDE
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on request. Siemens has released updates for the affected products, and recommends to update them to the latest version.
- SSA-538778SSA-538778: SmartVNC Vulnerabilities in SIMATIC HMI/WinCC Products2021-05-11csaf · siemens_psirtDE
Multiple SmartVNC vulnerabilities in the affected products listed below could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest version.
- ICSA-21-131-04Siemens SINAMICS Medium Voltage Products Remote Access (Update B)2021-05-11icsa · cisa_csaf_otUS
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on request. Siemens has released updates for the affected products, and recommends to update them to the latest version.
- ICSA-21-131-12Siemens SIMATIC SmartVNC HMI WinCC Products (Update B)2021-05-11icsa · cisa_csaf_otUS
Multiple SmartVNC vulnerabilities in the affected products listed below could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest version.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (12)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfcnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12cnnvd
- https://vigilance.fr/vulnerability/SmartVNC-multiple-vulnerabilities-35360cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2021051206cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfenisa_euvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.