CVE-2021-22797

highPriorität · verfolgen · 40EPSS 0.261 · 98. PerzentilEUUS
grimoire priorityP1 · Urgent
Exploitable?
—
no known exploitation
Likely / severe?
26.1% (98th) EPSS
CVSS 9.3 · high
Is it mine?
12 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenEcoStruxure Control Expertcisa_csaf_ot

    Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.

  • BehobenEcoStruxure Process Expertcisa_csaf_ot

    Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.

  • BehobenSCADAPack RemoteConnect for x70cisa_csaf_ot

    Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.

  • MitigationEcoStruxure Control Expertcisa_csaf_ot

    Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.

  • MitigationEcoStruxure Process Expertcisa_csaf_ot

    Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.

  • MitigationSCADAPack RemoteConnect for x70cisa_csaf_ot

    Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.3
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.09.3highAV:N/AC:M/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 10
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.07.8highCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · cybersecurity@se.comAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (12)

Betroffene Produkte und Versionsbereiche.

05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-21-259-02Schneider Electric EcoStruxure and SCADAPack2021-09-16icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could result in code execution on the engineering workstation.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2022-04-13geändert 2026-06-17
08

Referenzen (6)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan