CVE-2021-22778
lowPriorität · verfolgen · 28EPSS 0.002 · 12. PerzentilEURUUSEPSS · bewertet 2026-10-27
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationEcoStruxure Control Expertcisa_csaf_ot
Schneider Electric provides detailed mitigation information for each of the affected products in their own advisory, for more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-194-01.
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 - MitigationEcoStruxure Process Expertcisa_csaf_ot
Schneider Electric provides detailed mitigation information for each of the affected products in their own advisory, for more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-194-01.
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 - MitigationModicon M340 CPU (part numbers BMXP34*)cisa_csaf_ot
Schneider Electric provides detailed mitigation information for each of the affected products in their own advisory, for more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-194-01.
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 - MitigationModicon M580 CPU (part numbers BMEP* and BMEH*)cisa_csaf_ot
Schneider Electric provides detailed mitigation information for each of the affected products in their own advisory, for more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-194-01.
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 - MitigationSCADAPack RemoteConnect for x70cisa_csaf_ot
Schneider Electric provides detailed mitigation information for each of the affected products in their own advisory, for more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-194-01.
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–high · 3.6–8.6
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (20)
Betroffene Produkte und Versionsbereiche.
- n/a EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions≤ EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versionsenisa_euvdEU
- schneider-electric ecostruxure control expert< 15.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure control expert= 15.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure process expertalle VersionennvdUScpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*
- schneider-electric remoteconnectalle VersionennvdUScpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-21-194-02Schneider Electric Modicon Controllers and Software (Update A)2021-07-13icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities may allow arbitrary code execution and loss of confidentiality and integrity of the project file.
auch bekannt als (5)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01cnnvd
- https://www.auscert.org.au/bulletins/ESB-2021.2406cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2021071414cnnvd
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01enisa_euvd
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01Vendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan