CVE-2020-7534
mediumPriorität · verfolgen · 35EPSS 0.004 · 29. PerzentilEURUUSEPSS · bewertet 2026-10-27
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet (Copro): 140CPU65 (All Versions), Modicon Premium CPUs with integrated Ethernet (Copro): TSXP57 (All Versions), Modicon M340 ethernet modules: (BMXNOC0401, BMXNOE01, BMXNOR0200H) (All Versions), Modicon Quantum and Premium factory cast communication modules: (140NOE77111, 140NOC78*00, TSXETY5103, TSXETY4103) (All Versions)
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–8.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (21)
Betroffene Produkte und Versionsbereiche.
- n/a Modicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet (Copro): 140CPU65 (All Versions), Modicon Premium CPUs with integrated Ethernet (Copro): TSXP57 (All Versions), Modicon M340 ethernet modules: (BMXNOC0401, BMXNOE01, BMXNOR0200H) (All Versions), Modicon Quantum and Premium factory cast communication modules: (140NOE77111, 140NOC78*00, TSXETY5103, TSXETY4103)≤ Modicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet (Copro): 140CPU65 (All Versions), Modicon Premium CPUs with integrated Ethernet (Copro): TSXP57 (All Versions), Modicon M340 ethernet modules: (BMXNOC0401, BMXNOE01, BMXNOR0200H) (All Versions), Modicon Quantum and Premium factory cast communication modules: (140NOE77111, 140NOC78*00, TSXETY5103, TSXETY4103) (All Versions)enisa_euvdEU
- schneider-electric 140cpu65 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:140cpu65_firmware:*:*:*:*:*:*:*:*
- schneider-electric 140noc78000 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:140noc78000_firmware:*:*:*:*:*:*:*:*
- schneider-electric 140noe77111 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:140noe77111_firmware:*:*:*:*:*:*:*:*
- schneider-electric bmxnoc0401 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:bmxnoc0401_firmware:*:*:*:*:*:*:*:*
- schneider-electric bmxnoe01 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:bmxnoe01_firmware:*:*:*:*:*:*:*:*
- schneider-electric bmxnor0200h firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:bmxnor0200h_firmware:*:*:*:*:*:*:*:*
- schneider-electric modicon m340 bmxp342020 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:*:*:*:*:*:*:*:*
- schneider-electric tsxety4103 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:tsxety4103_firmware:*:*:*:*:*:*:*:*
- schneider-electric tsxety5103 firmwarealle VersionennvdUScpe:2.3:o:schneider-electric:tsxety5103_firmware:*:*:*:*:*:*:*:*
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (4)
Externe Belege — Patches, Meldungen, Analysen.
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2020-7534cnnvd
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01enisa_euvd
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01PatchVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.