Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationMicroLogix 1100 Controllercisa_csaf_ot
Rockwell Automation reports that there are currently no mitigations for MicroLogix 1400 series A controllers or MicroLogix 1100 controllers.
- MitigationRSLogix 500 Softwarecisa_csaf_ot
Rockwell Automation reports that there are currently no mitigations for MicroLogix 1400 series A controllers or MicroLogix 1100 controllers.
- MitigationSeries Acisa_csaf_ot
Rockwell Automation reports that there are currently no mitigations for MicroLogix 1400 series A controllers or MicroLogix 1100 controllers.
- MitigationSeries Bcisa_csaf_ot
Rockwell Automation reports that there are currently no mitigations for MicroLogix 1400 series A controllers or MicroLogix 1100 controllers.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 2.1–4
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (17)
Betroffene Produkte und Versionsbereiche.
- n/a Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior≤ Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and priorenisa_euvdEU
- rockwellautomation micrologix 1100 firmwarealle VersionennvdUScpe:2.3:o:rockwellautomation:micrologix_1100_firmware:*:*:*:*:*:*:*:*
- rockwellautomation micrologix 1400 a firmwarealle VersionennvdUScpe:2.3:o:rockwellautomation:micrologix_1400_a_firmware:*:*:*:*:*:*:*:*
- rockwellautomation micrologix 1400 b firmware≤ 21.001nvdUScpe:2.3:o:rockwellautomation:micrologix_1400_b_firmware:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-20-070-06Rockwell Automation MicroLogix Controllers and RSLogix 500 Software2020-03-10icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to gain access to sensitive project file information including passwords.
auch bekannt als (5)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.nsfocus.net/vulndb/46116cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2020-6980cnnvd
- https://www.rockwellautomation.com/Patchcnnvd
- https://www.us-cert.gov/ics/advisories/icsa-20-070-06cnnvd
- https://www.us-cert.gov/ics/advisories/icsa-20-070-06enisa_euvd
- https://www.us-cert.gov/ics/advisories/icsa-20-070-06Third Party AdvisoryUS Government Resourcenvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan