CVE-2020-6961

highPriorität · verfolgen · 41EPSS 0.016 · 76. PerzentilEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.62% (76th) EPSS
CVSS 7.5 · high
Is it mine?
29 products
Prüfe deine Angriffsfläche
Who says so?
3 sources
cnnvd · enisa_euvd · cisa_csaf_ot

EPSS · bewertet 2026-10-27

In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenApexPro Telemetry Servercisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

  • BehobenB450cisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

  • BehobenB650cisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

  • BehobenB850cisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

  • BehobenCARESCAPE Central Station (CSCS)cisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

  • BehobenCARESCAPE Telemetry Servercisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

  • BehobenClinical Information Center (CIC)cisa_csaf_ot

    GE recommends that, in addition to applying network management best practices, users ensure:

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

10.0
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.5–10

v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 6.4
v3.110criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 6
v3.010criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · CISA US
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (29)

Betroffene Produkte und Versionsbereiche.

20 von 29 angezeigt
05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSMA-20-023-01GE CARESCAPE, ApexPro, and Clinical Information Center systems2020-01-23icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could occur when an attacker gains access to the mission critical (MC) and/or information exchange (IX) networks due to improper configuration or physical access to devices. An exploit could result in a loss of monitoring and/or loss of alarms during active patient monitoring. These vulnerabilities, if exploited, may allow an attacker to obtain PHI data, make changes at the operating system level of the device, with effects such as rendering the device unusable, otherwise interfering with the function of the device and/or making certain changes to alarm settings on connected patient monitors, and/or utilizing services used for remote viewing and control of devices on the network to access the clinical user interface and make changes to device settings and alarm limits, which could result in missed or unnecessary alarms or silencing of some alarms.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2020-01-24geändert 2026-06-17
09

Referenzen (7)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan