CVE-2020-28396

mediumPriorität · verfolgen · 29OT-Risiko · erhöhtEPSS 0.006 · 47. PerzentilEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.57% (47th) EPSS
CVSS 4.9 · medium
Is it mine?
15 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-23

A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V16), SICAM A8000 CP-8021 (All versions < V16), SICAM A8000 CP-8022 (All versions < V16). A web server misconfiguration of the affected device can cause insecure ciphers usage by a user´s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.9–8.1

v2.04.9mediumAV:N/AC:M/Au:S/C:P/I:P/A:Nprimary · NVD / NIST USAusnutzbarkeit 6.8 · Auswirkung 4.9
v3.17.3highCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.1 · Auswirkung 5.2
v3.18.1highCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.17.3highAV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:Nsecondary · FSTEC (BDU) RU
v3.16.7mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (15)

Betroffene Produkte und Versionsbereiche.

05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-20-343-07Siemens SICAM A8000 RTUs2020-12-08icsa · cisa_csaf_otUS

    Operators of critical power systems (e.g.'TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g.'firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Digital Grid Products can be found at:

06

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2020-12-14geändert 2026-06-17
09

Referenzen (9)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan