CVE-2020-28383

mediumPriorität · verfolgen · 32EPSS 0.036 · 89. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
3.59% (89th) EPSS
CVSS 6.8 · medium
Is it mine?
14 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenJT2Gosiemens_psirt

    Update to V13.1.0.1 or later version

    https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html
  • BehobenTeamcenter Visualizationsiemens_psirt

    Update to V13.1.0.1 or later version

  • BehobenSolid Edge SE2020cisa_csaf_ot

    Update to Version SE2020MP12 or later

  • BehobenSolid Edge SE2021cisa_csaf_ot

    Update to Version SE2021MP2 or later

  • BehobenJT2Gocisa_csaf_ot

    Update to V13.1.0.1 or later version

    https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html
  • BehobenTeamcenter Visualizationcisa_csaf_ot

    Update to V13.1.0.1 or later version

  • MitigationJT2Gosiemens_psirt

    Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization

  • MitigationTeamcenter Visualizationsiemens_psirt

    Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization

  • MitigationSolid Edge SE2020cisa_csaf_ot

    Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity

  • MitigationSolid Edge SE2021cisa_csaf_ot

    Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity

  • MitigationJT2Gocisa_csaf_ot

    Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization

  • MitigationTeamcenter Visualizationcisa_csaf_ot

    Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.8–7.8

v2.06.8mediumAV:N/AC:M/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 6.4
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (14)

Betroffene Produkte und Versionsbereiche.

05

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-663999SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.12021-02-09csaf · siemens_psirtDE

    Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, PAR, ASM, DXF, DWG). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution or data extraction on the target host system. Siemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products. Notes: - Previous versions of this advisory incorrectly listed the following vulnerabilities as being fixed in V13.1.0.1: CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001 and CVE-2020-27002. Those were fixed in V13.1.0.2 and are therefore addressed in advisory SSA-695540 [0] - The vulnerability CVE-2020-28383 was incorrectly listed in SSA-622830 [1] as being fixed in V13.1.0.0. This was fixed in V13.1.0.1 and therefore added here - The Open Design Alliance [2] recently disclosed an additional vulnerability (CVE-2021-31784) which is also covered in this advisory [0] https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf [1] https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf [2] https://www.opendesign.com/security-advisories

  • ICSA-21-012-04Siemens Solid Edge2021-01-12icsa · cisa_csaf_otUS

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

  • ICSA-21-047-01Open Design Alliance Drawings SDK (Update A)2021-02-09icsa · cisa_csaf_otUS

    Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, PAR, ASM, DXF, DWG). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution or data extraction on the target host system. Siemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products. Notes: - Previous versions of this advisory incorrectly listed the following vulnerabilities as being fixed in V13.1.0.1: CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001 and CVE-2020-27002. Those were fixed in V13.1.0.2 and are therefore addressed in advisory SSA-695540 [0] - The vulnerability CVE-2020-28383 was incorrectly listed in SSA-622830 [1] as being fixed in V13.1.0.0. This was fixed in V13.1.0.1 and therefore added here - The Open Design Alliance [2] recently disclosed an additional vulnerability (CVE-2021-31784) which is also covered in this advisory [0] https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf [1] https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf [2] https://www.opendesign.com/security-advisories

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2021-01-12geändert 2026-06-17
08

Referenzen (25)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan