CVE-2020-1603

highPriorität · verfolgen · 34EPSS 0.014 · 72. PerzentilEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.41% (72nd) EPSS
CVSS 7.8 · high
Is it mine?
50 products
Prüfe deine Angriffsfläche
Who says so?
3 sources
cnnvd · enisa_euvd · fstec_bdu

EPSS · bewertet 2026-10-27

Specific IPv6 packets sent by clients processed by the Routing Engine (RE) are improperly handled. These IPv6 packets are designed to be blocked by the RE from egressing the RE. Instead, the RE allows these specific IPv6 packets to egress the RE, at which point a mbuf memory leak occurs within the Juniper Networks Junos OS device. This memory leak eventually leads to a kernel crash (vmcore), or the device hanging and requiring a power cycle to restore service, creating a Denial of Service (DoS) condition. During the time where mbufs are rising, yet not fully filled, some traffic from client devices may begin to be black holed. To be black holed, this traffic must match the condition where this traffic must be processed by the RE. Continued receipt and attempted egress of these specific IPv6 packets from the Routing Engine (RE) will create an extended Denial of Service (DoS) condition. Scenarios which have been observed are: 1. In a single chassis, single RE scenario, the device will hang without vmcore, or a vmcore may occur and then hang. In this scenario the device needs to be power cycled. 2. In a single chassis, dual RE scenario, the device master RE will fail over to the backup RE. In this scenario, the master and the backup REs need to be reset from time to time when they vmcore. There is no need to power cycle the device. 3. In a dual chassis, single RE scenario, the device will hang without vmcore, or a vmcore may occur and then hang. In this scenario, the two chassis' design relies upon some type of network level redundancy - VRRP, GRES, NSR, etc. - 3.a In a commanded switchover, where nonstop active routing (NSR) is enabled no session loss is observed. 4. In a dual chassis, dual chassis scenario, rely upon the RE to RE failover as stated in the second scenario. In the unlikely event that the device does not switch RE to RE gracefully, then the fallback position is to the network level services scenario in the third scenario. This issue affects: Juniper Networks Junos OS 16.1 versions prior to 16.1R7-S6; 16.1 version 16.1X70-D10 and later; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R2-S8, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D50, 18.2X75-D410; 18.3 versions prior to 18.3R1-S6, 18.3R2-S2, 18.3R3; 18.4 versions prior to 18.4R1-S6, 18.4R2-S2, 18.4R3; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect releases prior to Junos OS 16.1R1.

01

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.6
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.07.8highAV:N/AC:L/Au:N/C:N/I:N/A:Cprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 6.9
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 4
v3.18.6highAV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · ENISA EU
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · sirt@juniper.net USAusnutzbarkeit 3.9 · Auswirkung 4
v3.17.9highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
02

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

03

betroffene Produkte (50)

Betroffene Produkte und Versionsbereiche.

20 von 50 angezeigt
04

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

05

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2020-01-15geändert 2026-06-17
07

Referenzen (15)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan