CVE-2020-12499
mediumPriorität · verfolgen · 29EPSS 0.004 · 34. PerzentilDEEUUSEPSS · bewertet 2026-10-27
In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenPLCnext Engineerphoenix_contact_psirt
Phoenix Contact strongly recommends updating to the latest version PLCnext Enineer 2020.6, which fixes this vulnerability.
- Behobenpilz_psirt
Use the current Version 7.10 of the Software CodeMeter Runtime, available via the manufacturer's website. https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html Only use the Software CodeMeter Runtime as Client. The software tools named under affected products use the Software CodeMeter Runtime as Client in their default setting. Pilz also recommends using a local firewall to limit unwanted access to the network ser- vices of the device with Software CodeMeter Runtime installed.
- MitigationPLCnext Engineerphoenix_contact_psirt
We strongly recommend customers to exchange project files only using secure file exchange services. Project files should not be exchanged via unencrypted email. Users should avoid importing project files from unknown source and exchange or store project files together with a checksum to ensure their integrity.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 4.4–9.8
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (20)
Betroffene Produkte und Versionsbereiche.
- phoenixcontact plcnext engineer≤ 2020-3-1nvdUScpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- VDE-2020-025PHOENIX CONTACT: Improper path sanitation on import of project files in PLCnext Engineer2020-07-21csaf · phoenix_contact_psirtDE
The build settings of a PLCnext Engineer project (.pcwex) can be manipulated in a way that can result in the execution of remote code. The attacker needs to get access to a PLCnext Engineer project to be able to manipulate files inside. Additionally, the files of the remote code need to be transferred to a location which can be accessed by the PC that runs PLCnext Engineer. When PLCnext Engineer runs a build process of the manipulated project the remote code can be executed.
- VDE-2020-033Pilz: Multiple products prone to WIBU-SYSTEMS CodeMeter vulnerabilities2020-09-10csaf · pilz_psirtDE
A number of Pilz software tools use the Software CodeMeter Runtime application from WIBU-SYSTEMS AG to manage licences. This application contains a number of vulnerabilities, which enable an attacker to change and falsify a licence file, prevent normal operation of Code- Meter (Denial-of-Service) and potentially execute arbitrary code.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan