CVE-2019-6585

mediumPriorität · verfolgen · 24EPSS 0.007 · 54. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.74% (54th) EPSS
CVSS 4.3 · medium
Is it mine?
20 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenSCALANCE S602siemens_psirt

    Update to V4.1

  • BehobenSCALANCE S612siemens_psirt

    Update to V4.1

  • BehobenSCALANCE S623siemens_psirt

    Update to V4.1

  • BehobenSCALANCE S627-2Msiemens_psirt

    Update to V4.1

  • BehobenSCALANCE S602cisa_csaf_ot

    Update to V4.1

  • BehobenSCALANCE S612cisa_csaf_ot

    Update to V4.1

  • BehobenSCALANCE S623cisa_csaf_ot

    Update to V4.1

  • BehobenSCALANCE S627-2Mcisa_csaf_ot

    Update to V4.1

  • MitigationSCALANCE S602siemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S612siemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S623siemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S627-2Msiemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S602cisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S612cisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S623cisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S627-2Mcisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.04.3mediumAV:N/AC:M/Au:N/C:N/I:P/A:Nprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 2.9
v3.16.1mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 2.7
v3.14.7mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.14.7mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.15.6mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (20)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-591405SSA-591405: Web Vulnerabilities in SCALANCE S-600 Family2020-02-11csaf · siemens_psirtDE

    The firmware for SCALANCE S-600 family devices contains multiple web vulnerabilities. The vulnerabilities could allow an remote attacker to conduct Denial-of-Service attacks or perform Cross-Site Scripting attacks. Siemens has released updates for the affected products and recommends to update to the latest versions, or to upgrade to a successor product.

  • ICSA-20-042-10Siemens SCALANCE S-600 (Update B)2020-02-11icsa · cisa_csaf_otUS

    The firmware for SCALANCE S-600 family devices contains multiple web vulnerabilities. The vulnerabilities could allow an remote attacker to conduct Denial-of-Service attacks or perform Cross-Site Scripting attacks. Siemens has released updates for the affected products and recommends to update to the latest versions, or to upgrade to a successor product.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2020-03-10geändert 2026-06-17
08

Referenzen (20)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan