CVE-2019-6569

mediumPriorität · verfolgen · 36EPSS 0.013 · 71. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.33% (71st) EPSS
CVSS 6.4 · medium
Is it mine?
477 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 5.4–9.1

v2.06.4mediumAV:N/AC:L/Au:N/C:P/I:N/A:Pprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 4.9
v3.19.1criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 5.2
v3.15.4mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:L/E:P/RL:O/RC:Csecondary · CISA US
v3.19.1criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.15.4mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:L/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.18.3highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (477)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-557804SSA-557804: Mirror Port Isolation Vulnerability in SCALANCE X Switches2019-03-12csaf · siemens_psirtDE

    A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-19-085-01Siemens SCALANCE X (Update D)2019-03-12icsa · cisa_csaf_otUS

    A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

08

Referenzen (10)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan