Path traversal in RadChart in Telerik UI for ASP.NET AJAX allows a remote attacker to read and delete an image with extension .BMP, .EXIF, .GIF, .ICON, .JPEG, .PNG, .TIFF, or .WMF on the server through a specially crafted request. NOTE: RadChart was discontinued in 2014 in favor of RadHtmlChart. All RadChart versions were affected. To avoid this vulnerability, you must remove RadChart's HTTP handler from a web.config (its type is Telerik.Web.UI.ChartHttpHandler).

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobeneSOMScisa_csaf_ot

    Hitachi ABB Power Grids has published an advisory for eSOMS Telerik and advises users to update to eSOMS Version 6.3 as soon as possible.

    https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8943&LanguageCode=en&DocumentPartId=&Action=Launch
  • MitigationeSOMScisa_csaf_ot

    Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include ensuring applications and servers are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Sensitive application servers should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.5–9.8

v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 6.4
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 5.9
v3.09.8criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (5)

Betroffene Produkte und Versionsbereiche.

05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-21-077-03Hitachi ABB Power Grids eSOMS Telerik2021-03-18icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to upload malicious files to the server, discover sensitive information, or execute arbitrary code.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2019-12-13geändert 2026-06-17
09

Referenzen (13)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan