CVE-2019-19645
lowPriorität · verfolgen · 22EPSS 0.006 · 46. PerzentilCHDEEURUUSEPSS · bewertet 2026-10-23
alter.c in SQLite through 3.30.1 allows attackers to trigger infinite recursion via certain types of self-referential views in conjunction with ALTER TABLE statements.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenAbility Camera Connectabb_psirt
The problem is corrected in the following product versions: - ABB Ability Camera Connect 2.0.0.49. The easiest path to mitigate the problem is an update of ABB Ability Camera Connect system by the customer. ABB recommends that customers apply the update at earliest convenience.
- BehobenAutomation Studioabb_psirt
The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
- BehobenSINEC INSsiemens_psirt
Update to V1.0.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109806100/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSINEC INScisa_csaf_ot
Update to V1.0.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109806100/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenB&R Automation Studiocisa_csaf_ot
The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
- MitigationAbility Camera Connectabb_psirt
This vulnerability involves database views and schema modification: - View Usage: This vulnerability requires self-referential database views, which are advanced database con-structs. Camera Connect's database schema uses standard tables and simple views without self-referential patterns. - ALTER TABLE Requirement: Triggering the vulnerability requires ALTER TABLE operations, which are administrative schema modification commands not available to normal users. - Infinite Recursion Detection: Modern operating systems and runtime environments typically include stack overflow protection and recursion detection that can terminate runaway processes. - Schema Design: Self-referential views represent poor database design practices that would be identified and corrected during development review. - Static Schema: Camera Connect's database schema is static and managed through formal change control, pre-venting the introduction of problematic self-referential view patterns. The requirement for both specialized view design and administrative schema modification makes this vulnerability in-applicable to Camera Connect's operational environment.
- MitigationAutomation Studioabb_psirt
Refer to section “General security recommendations” for advice on how to keep your system secure.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationB&R Automation Studiocisa_csaf_ot
Refer to section “General security recommendations” for advice on how to keep your system secure.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 2.1–5.5
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (42)
Betroffene Produkte und Versionsbereiche.
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
Advisories (10)
Hersteller- und Ökosystem-Meldungen dazu.
- 4HZM000604ABB Ability Camera Connect Vulnerabilities in outdated 3rd party component (SQLite 3.2.4)2026-03-26csaf · abb_psirtCH
ABB is aware of public reports of vulnerabilities in a 3rd party dependency SQLite Version 3.2.4 which was delivered together with the installation package of Camera Connect Version 2.0.0.42 and below. An update is available that resolves a privately reported outdated 3rd party component with vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited any of these vulnerabilities in the 3rd party component could potentially compromise the system in different ways.
- SA25P007B&R Automation Studio Update of SQLite version2026-02-18csaf · abb_psirtCH
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution.
- SSA-389290SSA-389290: Third-Party Component Vulnerabilities in SINEC INS2022-03-08csaf · siemens_psirtDE
71 vulnerabilities in third-party components as Node.js, cURL, SQLite, CivetWeb and DNS(ISC BIND) could allow an attacker to interfere with the affected product in various ways. Siemens has released an update for SINEC INS and recommends to update to the latest versions.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- WID-SEC-W-2023-1049Oracle MySQL: Mehrere SchwachstellenDeutsch2020-04-14csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Verfügbarkeit, Vertraulichkeit und Integrität zu gefährden.
- WID-SEC-W-2023-1614Tenable Security Nessus Network Monitor: Mehrere SchwachstellenDeutsch2023-06-29csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in Tenable Security Nessus Network Monitor ausnutzen, um beliebigen Code auszuführen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszulösen und Daten zu manipulieren.
- WID-SEC-W-2026-0180Dell Data Protection Advisor: Mehrere SchwachstellenDeutsch2026-01-20csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell Data Protection Advisor ausnutzen, um beliebigen Code auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Sicherheitsmaßnahmen zu umgehen und nicht näher spezifizierte Angriffe zu starten.
- ICSA-22-069-09Siemens SINEC INS2022-03-08icsa · cisa_csaf_otUS
71 vulnerabilities in third-party components as Node.js, cURL, SQLite, CivetWeb and DNS(ISC BIND) could allow an attacker to interfere with the affected product in various ways. Siemens has released an update for SINEC INS and recommends to update to the latest versions.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-26-141-03ABB B&R Automation Studio2026-02-18icsa · cisa_csaf_otUS
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (33)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfcnnvd
- https://github.com/sqlite/sqlite/commit/38096961c7cd109110ac21d3ed7dad7e0cb0ae06cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2019-19645cnnvd
- https://packetstormsecurity.com/files/158024/Ubuntu-Security-Notice-USN-4394-1.htmlcnnvd
- https://security.netapp.com/advisory/ntap-20191223-0001/cnnvd
- https://support.lenovo.com/us/en/product_security/LEN-60182cnnvd
- https://usn.ubuntu.com/4394-1/cnnvd
- https://vigilance.fr/vulnerability/SQLite-denial-of-service-via-Unused-CTE-View-Recursion-31102cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan