CVE-2019-19291

lowPriorität · verfolgen · 14OT-Risiko · erhöhtEPSS 0.007 · 55. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.75% (55th) EPSS
CVSS 3.5 · low
Is it mine?
10 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0). The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server (CCS) maintain log files that store login credentials in cleartext. In configurations where the FTP service is enabled, authenticated remote attackers could extract login credentials of other users of the service.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenControl Center Server (CCS)siemens_psirt

    Update to V1.5.0 or later version

  • BehobenSiNVR/SiVMS Video Serversiemens_psirt

    Update to V5.0.0 or later version

  • BehobenControl Center Server (CCS)cisa_csaf_ot

    Update to V1.5.0 or later version

  • BehobenControl Center Server (CCS)cisa_csaf_ot

    Update to V1.5.0 or later version

    https://sivms.cloud/control-center-server-ccs/
  • MitigationControl Center Server (CCS)siemens_psirt

    Apply ACL/firewall configuration on the CCS server to ensure that only legitimate systems are able to access the configured CCS server ports. Harden the CCS server accordingly to prevent unauthorized access. Consider to apply encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level).

  • MitigationSiNVR/SiVMS Video Serversiemens_psirt

    Apply ACL/firewall configuration on the Video Servers to ensure that only legitimate systems are able to access the configured server ports. Harden all systems accordingly to prevent unauthorized access Consider to apply encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level)

  • MitigationControl Center Server (CCS)cisa_csaf_ot

    Apply ACL/firewall configuration on the CCS server to ensure that only legitimate systems are able to access the configured CCS server ports. Harden the CCS server accordingly to prevent unauthorized access. Consider to apply encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level).

  • MitigationControl Center Server (CCS)cisa_csaf_ot

    As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 3–6.5

v2.03.5lowAV:N/AC:M/Au:S/C:P/I:N/A:Nprimary · NVD / NIST USAusnutzbarkeit 6.8 · Auswirkung 2.9
v2.03lowAV:N/AC:M/Au:S/C:P/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
v3.15.3mediumCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:Csecondary · CISA US
v3.16.5mediumAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.15.3mediumCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:Csecondary · ENISA EU
v3.15.3mediumCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:Nsecondary · productcert@siemens.com DEAusnutzbarkeit 1.6 · Auswirkung 3.6
v3.15.3mediumCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:Csecondary · Siemens ProductCERT DE
v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:Nsecondary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 3.6
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (10)

Betroffene Produkte und Versionsbereiche.

05

Advisories (4)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-761844SSA-761844: Multiple Vulnerabilities in Control Center Server (CCS)2021-04-13csaf · siemens_psirtDE

    The advisory informs about multiple vulnerabilities in the Central Control Server (CCS) application, as initially reported in SSA-761617 ( https://cert-portal.siemens.com/productcert/html/ssa-761617.html) on 2019-12-10 and SSA-844761 (https://cert-portal.siemens.com/productcert/html/ssa-844761.html) on 2020-03-10. The vulnerabilities involve authentication bypass (CVE-2019-18337, CVE-2019-18341), path traversal (CVE-2019-18338, CVE-2019-19290), information disclosure (CVE-2019-13947, CVE-2019-18340, CVE-2019-19291), privilege escalation (CVE-2019-18342), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), and insufficient logging (CVE-2019-19295). PKE has released an update for CCS that fixes the reported vulnerabilities, except for CVE-2019-18340. For details contact PKE ( https://pke.at/). Siemens recommends to update to the latest version and recommends specific countermeasures to mitigate the vulnerabilities.

  • SSA-844761SSA-844761: Multiple Vulnerabilities in SiNVR/SiVMS Video Server2020-03-10csaf · siemens_psirtDE

    The Video Server application in SiNVR/SiVMS solutions contains five vulnerabilities involving information disclosure (CVE-2019-19291, CVE-2019-19299), path traversal (CVE-2019-19296, CVE-2019-19297), and denial-of-service (CVE-2019-19298). PKE has released updates of the application that fixes the reported vulnerabilities, except for CVE-2019-19299. This update is not available under the former Siemens OEM brand name SiNVR. For details contact PKE ( https://pke.at/).

  • ICSA-20-070-01ICSA-20-070-01_Siemens and PKE SiNVR/SiVMS Video Server (Update B)2021-04-13icsa · cisa_csaf_otUS

    The advisory informs about multiple vulnerabilities in the Central Control Server (CCS) application, as initially reported in SSA-761617 ( https://cert-portal.siemens.com/productcert/html/ssa-761617.html) on 2019-12-10 and SSA-844761 (https://cert-portal.siemens.com/productcert/html/ssa-844761.html) on 2020-03-10. The vulnerabilities involve authentication bypass (CVE-2019-18337, CVE-2019-18341), path traversal (CVE-2019-18338, CVE-2019-19290), information disclosure (CVE-2019-13947, CVE-2019-18340, CVE-2019-19291), privilege escalation (CVE-2019-18342), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), and insufficient logging (CVE-2019-19295). PKE has released an update for CCS that fixes the reported vulnerabilities, except for CVE-2019-18340. For details contact PKE ( https://pke.at/). Siemens recommends to update to the latest version and recommends specific countermeasures to mitigate the vulnerabilities.

  • ICSA-21-103-10Siemens and PKE Control Center Server2021-04-13icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities may allow an attacker to read and write arbitrary files and sensitive data and execute commands and arbitrary code.

06