CVE-2019-19282
highPriorität · verfolgen · 28EPSS 0.013 · 71. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenOpenPCS 7 V9.0siemens_psirt
See remediation for SIMATIC PCS 7 V9.0
- BehobenSIMATIC BATCH V8.2siemens_psirt
Update to V8.2 Upd12 or later version
https://support.industry.siemens.com/cs/ww/en/view/109757796/ - BehobenSIMATIC BATCH V9.0siemens_psirt
See remediation for SIMATIC PCS 7 V9.0
- BehobenSIMATIC NET PC Software V14siemens_psirt
Update to V14 SP1 Update 14 or later version
https://support.industry.siemens.com/cs/ww/en/view/109807351/ - BehobenSIMATIC NET PC Software V16siemens_psirt
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109778547/ - BehobenSIMATIC PCS 7 V8.2siemens_psirt
Update to V8.2 SP1; then update SIMATIC WinCC to V7.4 SP1 Update 14 or later version on the same system
https://support.industry.siemens.com/cs/ww/en/view/109758443/ - BehobenSIMATIC PCS 7 V9.0siemens_psirt
Update to V9.0 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109780584/ - BehobenSIMATIC Route Control V9.0siemens_psirt
See remediation for SIMATIC PCS 7 V9.0
- BehobenSIMATIC WinCC (TIA Portal) V13siemens_psirt
Update to V13 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109759782/ - BehobenSIMATIC WinCC (TIA Portal) V14siemens_psirt
Update to V14 SP1 Update 10 or later version
https://support.industry.siemens.com/cs/us/en/view/109747387/ - BehobenSIMATIC WinCC (TIA Portal) V15.1siemens_psirt
Update to V15.1 Update 5 or later version
https://support.industry.siemens.com/cs/us/en/view/109763890/ - BehobenSIMATIC WinCC (TIA Portal) V16siemens_psirt
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC WinCC V7.4siemens_psirt
Update to V7.4 SP1 Update 14 or later version
https://support.industry.siemens.com/cs/us/en/view/109779373/ - BehobenSIMATIC WinCC V7.5siemens_psirt
Update to V7.5 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773812/ - BehobenOpenPCS 7 V9.0cisa_csaf_ot
See remediation for SIMATIC PCS 7 V9.0
- BehobenSIMATIC BATCH V8.2cisa_csaf_ot
Update to V8.2 Upd12 or later version
https://support.industry.siemens.com/cs/ww/en/view/109757796/ - BehobenSIMATIC BATCH V9.0cisa_csaf_ot
See remediation for SIMATIC PCS 7 V9.0
- BehobenSIMATIC NET PC Software V14cisa_csaf_ot
Update to V14 SP1 Update 14 or later version
https://support.industry.siemens.com/cs/ww/en/view/109807351/ - BehobenSIMATIC NET PC Software V16cisa_csaf_ot
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109778547/ - BehobenSIMATIC PCS 7 V8.2cisa_csaf_ot
Update to V8.2 SP1; then update SIMATIC WinCC to V7.4 SP1 Update 14 or later version on the same system
https://support.industry.siemens.com/cs/ww/en/view/109758443/ - BehobenSIMATIC PCS 7 V9.0cisa_csaf_ot
Update to V9.0 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109780584/ - BehobenSIMATIC Route Control V9.0cisa_csaf_ot
See remediation for SIMATIC PCS 7 V9.0
- BehobenSIMATIC WinCC (TIA Portal) V13cisa_csaf_ot
Update to V13 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109759782/ - BehobenSIMATIC WinCC (TIA Portal) V14cisa_csaf_ot
Update to V14 SP1 Update 10 or later version
https://support.industry.siemens.com/cs/us/en/view/109747387/ - BehobenSIMATIC WinCC (TIA Portal) V15.1cisa_csaf_ot
Update to V15.1 Update 5 or later version
https://support.industry.siemens.com/cs/us/en/view/109763890/ - BehobenSIMATIC WinCC (TIA Portal) V16cisa_csaf_ot
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC WinCC V7.4cisa_csaf_ot
Update to V7.4 SP1 Update 14 or later version
https://support.industry.siemens.com/cs/us/en/view/109779373/ - BehobenSIMATIC WinCC V7.5cisa_csaf_ot
Update to V7.5 SP1 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773812/ - MitigationOpenPCS 7 V8.1siemens_psirt
Use VPN for protecting network communication between cells
- MitigationOpenPCS 7 V8.2siemens_psirt
The vulnerability is fixed if SIMATIC WinCC V7.4 SP1 Update 14 or later version is installed on the same system
- MitigationOpenPCS 7 V9.0siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC BATCH V8.1siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC BATCH V8.2siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC BATCH V9.0siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC NET PC Software V14siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC NET PC Software V15siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC NET PC Software V16siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC PCS 7 V8.1siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC PCS 7 V8.2siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC PCS 7 V9.0siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC Route Control V8.1siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC Route Control V8.2siemens_psirt
The vulnerability is fixed if SIMATIC WinCC V7.4 SP1 Update 14 or later version is installed on the same system
- MitigationSIMATIC Route Control V9.0siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V13siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V14siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V15.1siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V16siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC V7.3siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC V7.4siemens_psirt
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC V7.5siemens_psirt
Use VPN for protecting network communication between cells
- MitigationOpenPCS 7 V8.1cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationOpenPCS 7 V8.2cisa_csaf_ot
The vulnerability is fixed if SIMATIC WinCC V7.4 SP1 Update 14 or later version is installed on the same system
- MitigationOpenPCS 7 V9.0cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC BATCH V8.1cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC BATCH V8.2cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC BATCH V9.0cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC NET PC Software V14cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC NET PC Software V15cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC NET PC Software V16cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC PCS 7 V8.1cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC PCS 7 V8.2cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC PCS 7 V9.0cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC Route Control V8.1cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC Route Control V8.2cisa_csaf_ot
The vulnerability is fixed if SIMATIC WinCC V7.4 SP1 Update 14 or later version is installed on the same system
- MitigationSIMATIC Route Control V9.0cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V13cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V14cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V15.1cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC (TIA Portal) V16cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC V7.3cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC V7.4cisa_csaf_ot
Use VPN for protecting network communication between cells
- MitigationSIMATIC WinCC V7.5cisa_csaf_ot
Use VPN for protecting network communication between cells
- Kein Fix geplantOpenPCS 7 V8.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V8.2siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC BATCH V8.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V15siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS 7 V8.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC Route Control V8.1siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC Route Control V8.2siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V7.3siemens_psirt
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V8.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantOpenPCS 7 V8.2cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC BATCH V8.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC NET PC Software V15cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS 7 V8.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC Route Control V8.1cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC Route Control V8.2cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC WinCC V7.3cisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6–7.5
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (126)
Betroffene Produkte und Versionsbereiche.
Advisories (3)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-270778SSA-270778: Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software2020-02-11csaf · siemens_psirtDE
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are not affected as encrypted communication is not an option). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. Note: The vulnerability is part of a shared component, used by various Siemens products (SIMATIC Communication Services - SCS). The installation of a fix version of any product also removes the vulnerability for other products on the same system, even if those products were not updated.
- WID-SEC-W-2023-0906Siemens SIMATIC WinCC: Schwachstelle ermöglicht Denial of ServiceDeutsch2023-04-10csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Siemens SIMATIC WinCC ausnutzen, um einen Denial of Service Angriff durchzuführen.
- ICSA-20-042-06Siemens SIMATIC PCS 7, SIMATIC WinCC, and SIMATIC NET PC (Update G)2020-02-11icsa · cisa_csaf_otUS
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are not affected as encrypted communication is not an option). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. Note: The vulnerability is part of a shared component, used by various Siemens products (SIMATIC Communication Services - SCS). The installation of a fix version of any product also removes the vulnerability for other products on the same system, even if those products were not updated.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (18)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdfcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2019-19282cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-20-042-06cnnvd
- https://www.auscert.org.au/bulletins/ESB-2020.0486.2/cnnvd
- https://www.auscert.org.au/bulletins/ESB-2020.0486.3/cnnvd
- https://www.auscert.org.au/bulletins/ESB-2020.0486/cnnvd
- https://www.us-cert.gov/ics/advisories/icsa-20-042-01cnnvd
- https://www.us-cert.gov/ics/advisories/icsa-20-042-02cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan