CVE-2019-1836
mediumPriorität · verfolgen · 28EPSS 0.004 · 38. PerzentilEURUUSEPSS · bewertet 2026-10-27
A vulnerability in the system shell for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to use symbolic links to overwrite system files. These system files may be sensitive and should not be overwritable by non-root users. The attacker would need valid device credentials. The vulnerability is due to incorrect symbolic link verification of directory paths when they are used in the system shell. An attacker could exploit this vulnerability by authenticating to the device and providing crafted user input to specific symbolic link CLI commands. Successful exploitation could allow the attacker to overwrite system files that should be restricted. This vulnerability has been fixed in software version 14.1(1i).
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenCisco NX-OS System Software in ACI Modecisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.5–7.1
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (4)
Betroffene Produkte und Versionsbereiche.
- Cisco Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Modeunspecified → 14.1(1i)enisa_euvdEU
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- cisco-sa-20190501-fabric-traversalCisco Nexus 9000 Series Fabric Switches Application Centric Infrastructure Mode Symbolic Link Path Traversal Vulnerability2019-05-01csaf · cisco_csafUS
A vulnerability in the system shell for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, local attacker to use symbolic links to overwrite system files. These system files may be sensitive and should not be overwritable by non-root users. The attacker would need valid device credentials. The vulnerability is due to incorrect symbolic link verification of directory paths when they are used in the system shell. An attacker could exploit this vulnerability by authenticating to the device and providing crafted user input to specific symbolic link CLI commands. Successful exploitation could allow the attacker to overwrite system files that should be restricted. There are no workarounds that address this vulnerability. This advisory is available at the following link: https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-fabric-traversal ["https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-fabric-traversal"]
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (13)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.cisco.com/cnnvd
- http://www.securityfocus.com/bid/108150cnnvd
- https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvo80695Patchcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2019-1836cnnvd
- https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-fabric-traversalcnnvd
- https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-nexus9k-rpecnnvd
- https://vigilance.fr/vulnerability/Cisco-Nexus-9000-ACI-privilege-escalation-via-Symbolic-Link-Path-Traversal-29185cnnvd
- https://www.auscert.org.au/bulletins/80070cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan