CVE-2019-13926

highPriorität · verfolgen · 31EPSS 0.015 · 74. PerzentilDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.50% (74th) EPSS
CVSS 7.8 · high
Is it mine?
24 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenSCALANCE S602siemens_psirt

    Update to V4.1

  • BehobenSCALANCE S612siemens_psirt

    Update to V4.1

  • BehobenSCALANCE S623siemens_psirt

    Update to V4.1

  • BehobenSCALANCE S627-2Msiemens_psirt

    Update to V4.1

  • BehobenSCALANCE S602cisa_csaf_ot

    Update to V4.1

  • BehobenSCALANCE S612cisa_csaf_ot

    Update to V4.1

  • BehobenSCALANCE S623cisa_csaf_ot

    Update to V4.1

  • BehobenSCALANCE S627-2Mcisa_csaf_ot

    Update to V4.1

  • MitigationSCALANCE S602siemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S612siemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S623siemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S627-2Msiemens_psirt

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S602cisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S612cisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S623cisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

  • MitigationSCALANCE S627-2Mcisa_csaf_ot

    Only access links from trusted sources in the browser you use to access the SCALANCE S-600 administration website.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.9–7.8

v2.07.8highAV:N/AC:L/Au:N/C:N/I:N/A:Cprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 6.9
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 3.6
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.5highAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (24)

Betroffene Produkte und Versionsbereiche.

20 von 24 angezeigt
05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-591405SSA-591405: Web Vulnerabilities in SCALANCE S-600 Family2020-02-11csaf · siemens_psirtDE

    The firmware for SCALANCE S-600 family devices contains multiple web vulnerabilities. The vulnerabilities could allow an remote attacker to conduct Denial-of-Service attacks or perform Cross-Site Scripting attacks. Siemens has released updates for the affected products and recommends to update to the latest versions, or to upgrade to a successor product.

  • ICSA-20-042-10Siemens SCALANCE S-600 (Update B)2020-02-11icsa · cisa_csaf_otUS

    The firmware for SCALANCE S-600 family devices contains multiple web vulnerabilities. The vulnerabilities could allow an remote attacker to conduct Denial-of-Service attacks or perform Cross-Site Scripting attacks. Siemens has released updates for the affected products and recommends to update to the latest versions, or to upgrade to a successor product.

06

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (20)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan