CVE-2019-13555

mediumPriorität · verfolgen · 25EPSS 0.015 · 74. PerzentilEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.52% (74th) EPSS
CVSS 4.3 · medium
Is it mine?
23 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationL02/06/26CPU L26CPU-BTcisa_csaf_ot

    Mitsubishi Electric strongly recommends that users should operate the affected device behind a firewall.

  • MitigationL02/06/26CPU-CM L26CPU-BT-CMcisa_csaf_ot

    Mitsubishi Electric strongly recommends that users should operate the affected device behind a firewall.

  • MitigationL02/06/26CPU-P L26CPU-PBTcisa_csaf_ot

    Mitsubishi Electric strongly recommends that users should operate the affected device behind a firewall.

  • MitigationQ03/04/06/13/26UDVCPUcisa_csaf_ot

    Mitsubishi Electric strongly recommends that users should operate the affected device behind a firewall.

  • MitigationQ03UDECPU Q04/06/10/13/20/26/50/100UDEHCPUcisa_csaf_ot

    Mitsubishi Electric strongly recommends that users should operate the affected device behind a firewall.

  • MitigationQ04/06/13/26UDPVCPUcisa_csaf_ot

    Mitsubishi Electric strongly recommends that users should operate the affected device behind a firewall.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.3–7.5

v2.04.3mediumAV:N/AC:M/Au:N/C:N/I:N/A:Pprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 2.9
v3.15.9mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 2.2 · Auswirkung 3.6
v3.07.5highCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · CISA US
v3.15.4mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (23)

Betroffene Produkte und Versionsbereiche.

20 von 23 angezeigt
05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-19-311-01Mitsubishi Electric MELSEC-Q Series and MELSEC-L Series CPU Modules2019-11-07icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability may prevent the FTP client from connecting to the FTP server on MELSEC-Q Series and MELSEC-L Series CPU module.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2019-11-13geändert 2026-06-17
09

Referenzen (6)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan