CVE-2019-13103

lowPriorität · verfolgen · 28EPSS 0.004 · 37. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.43% (37th) EPSS
CVSS 3.6 · low
Is it mine?
84 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A crafted self-referential DOS partition table will cause all Das U-Boot versions through 2019.07-rc4 to infinitely recurse, causing the stack to grow infinitely and eventually either crash or overwrite other data.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–high · 3.6–7.1

v2.03.6lowAV:L/AC:L/Au:N/C:N/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 4.9
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.2
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Hsecondary · CISA US
v3.17.1highAV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.16.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:Hsecondary · NCSC-NL NL
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (84)

Betroffene Produkte und Versionsbereiche.

05

Advisories (5)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2026-0147Kwetsbaarheden verholpen in Siemens-productenNL2026-05-13csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in verschillende (OT-)producten. Het gaat onder andere om producten in de Siemens RUGGEDCOM-, SCALANCE-, SIMATIC-, SIMIT-, SINAMICS-, SIPROTEC-, SENTRON- en Solid Edge-productreeksen.

  • SSA-577017SSA-577017: Multiple Vulnerabilities in Ruggedcom Rox Before 2.17.12026-05-12csaf · siemens_psirtDE

    Ruggedcom Rox before v2.17.1 contain multiple third-party vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • SSA-618620SSA-618620: Vulnerabilities in Boot Loader (U-Boot) of RUGGEDCOM ROS Devices2019-12-10csaf · siemens_psirtDE

    The boot loader within RUGGEDCOM ROS contains two vulnerabilities in the loading process of the operating system kernel. The more severe of these vulnerabilities could allow an attacker with local access to the device to execute arbitrary code on an affected device. Siemens recommends specific countermeasures to mitigate this issue.

  • ICSA-19-344-03Siemens RUGGEDCOM ROS (Update A)2019-12-10icsa · cisa_csaf_otUS

    The boot loader within RUGGEDCOM ROS contains two vulnerabilities in the loading process of the operating system kernel. The more severe of these vulnerabilities could allow an attacker with local access to the device to execute arbitrary code on an affected device. Siemens recommends specific countermeasures to mitigate this issue.

  • ICSA-26-134-16Siemens Ruggedcom Rox2026-05-12icsa · cisa_csaf_otUS

    Ruggedcom Rox before v2.17.1 contain multiple third-party vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

06

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (21)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan