CVE-2018-4848

mediumPriorität · verfolgen · 24EPSS 0.010 · 62. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.99% (62nd) EPSS
CVSS 4.3 · medium
Is it mine?
22 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.04.3mediumAV:N/AC:M/Au:N/C:N/I:P/A:Nprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 2.9
v3.06.1mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 2.7
v3.05.6mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:Usecondary · CVSS-BT (t0sche)
v3.15.8mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:Csecondary · CISA US
v3.15.8mediumAV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:Lsecondary · FSTEC (BDU) RU
v3.15.8mediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (22)

Betroffene Produkte und Versionsbereiche.

20 von 22 angezeigt
05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-480829SSA-480829: Cross-Site Scripting Vulnerabilities in SCALANCE X Switches2018-06-12csaf · siemens_psirtDE

    Two cross-site scripting (XSS) vulnerabilities were identified in the web server of several SCALANCE X switches. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-18-163-02Siemens SCALANCE X Switches (Update A)2018-06-12icsa · cisa_csaf_otUS

    Two cross-site scripting (XSS) vulnerabilities were identified in the web server of several SCALANCE X switches. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (8)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan