CVE-2018-4839
lowPriorität · verfolgen · 21EPSS 0.006 · 47. PerzentilDEEURUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenDIGSI 4siemens_psirt
Update to V4.92
https://support.industry.siemens.com/cs/ww/en/view/109740980 - BehobenEN100 Ethernet module DNP3 variantsiemens_psirt
Update to V1.05.00 and configure DIGSI 4 connection password
https://support.industry.siemens.com/cs/us/en/view/109745821 - BehobenEN100 Ethernet module IEC 61850 variantsiemens_psirt
Update to V4.30 and configure DIGSI 4 connection password
https://support.industry.siemens.com/cs/us/en/view/109745821 - BehobenSIPROTEC 4 7SD80siemens_psirt
Update to V4.70
https://support.industry.siemens.com/cs/us/en/view/109742758 - BehobenSIPROTEC 4 7SJ61siemens_psirt
Update to V4.96
https://support.industry.siemens.com/cs/us/en/view/109743551 - BehobenSIPROTEC 4 7SJ62siemens_psirt
Update to V4.96
https://support.industry.siemens.com/cs/us/en/view/109743551 - BehobenSIPROTEC 4 7SJ64siemens_psirt
Update to V4.96
https://support.industry.siemens.com/cs/us/en/view/109743551 - BehobenSIPROTEC 4 7SJ66siemens_psirt
Update to V4.30
https://support.industry.siemens.com/cs/us/en/view/109743555 - BehobenSIPROTEC Compact 7SJ80siemens_psirt
Update to V4.77
https://support.industry.siemens.com/cs/us/en/view/109742699 - BehobenSIPROTEC Compact 7SK80siemens_psirt
Update to V4.77
https://support.industry.siemens.com/cs/us/en/view/109742712 - BehobenDIGSI 4cisa_csaf_ot
Update to V4.92
https://support.industry.siemens.com/cs/ww/en/view/109740980 - BehobenEN100 Ethernet module DNP3 variantcisa_csaf_ot
Update to V1.05.00 and configure DIGSI 4 connection password
https://support.industry.siemens.com/cs/us/en/view/109745821 - BehobenEN100 Ethernet module IEC 61850 variantcisa_csaf_ot
Update to V4.30 and configure DIGSI 4 connection password
https://support.industry.siemens.com/cs/us/en/view/109745821 - BehobenSIPROTEC 4 7SD80cisa_csaf_ot
Update to V4.70
https://support.industry.siemens.com/cs/us/en/view/109742758 - BehobenSIPROTEC 4 7SJ61cisa_csaf_ot
Update to V4.96
https://support.industry.siemens.com/cs/us/en/view/109743551 - BehobenSIPROTEC 4 7SJ62cisa_csaf_ot
Update to V4.96
https://support.industry.siemens.com/cs/us/en/view/109743551 - BehobenSIPROTEC 4 7SJ64cisa_csaf_ot
Update to V4.96
https://support.industry.siemens.com/cs/us/en/view/109743551 - BehobenSIPROTEC 4 7SJ66cisa_csaf_ot
Update to V4.30
https://support.industry.siemens.com/cs/us/en/view/109743555 - BehobenSIPROTEC Compact 7SJ80cisa_csaf_ot
Update to V4.77
https://support.industry.siemens.com/cs/us/en/view/109742699 - BehobenSIPROTEC Compact 7SK80cisa_csaf_ot
Update to V4.77
https://support.industry.siemens.com/cs/us/en/view/109742712 - MitigationDIGSI 4siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module DNP3 variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module IEC 104 variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module IEC 61850 variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module Modbus TCP variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module PROFINET IO variantsiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationOther SIPROTEC 4 relayssiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationOther SIPROTEC Compact relayssiemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SD80siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ61siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ62siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ64siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ66siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC Compact 7SJ80siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC Compact 7SK80siemens_psirt
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationDIGSI 4cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module DNP3 variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module IEC 104 variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module IEC 61850 variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module Modbus TCP variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationEN100 Ethernet module PROFINET IO variantcisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationOther SIPROTEC 4 relayscisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationOther SIPROTEC Compact relayscisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SD80cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ61cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ62cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ64cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC 4 7SJ66cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC Compact 7SJ80cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- MitigationSIPROTEC Compact 7SK80cisa_csaf_ot
Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity) or contact customer care to find specific solutions.
- Kein Fix verfügbarEN100 Ethernet module IEC 104 variantsiemens_psirt
Currently no remediation is available
- Kein Fix verfügbarEN100 Ethernet module Modbus TCP variantsiemens_psirt
Currently no remediation is available
- Kein Fix verfügbarEN100 Ethernet module PROFINET IO variantsiemens_psirt
Currently no remediation is available
- Kein Fix verfügbarOther SIPROTEC 4 relayssiemens_psirt
Currently no remediation is available
- Kein Fix verfügbarOther SIPROTEC Compact relayssiemens_psirt
Currently no remediation is available
- Kein Fix verfügbarEN100 Ethernet module IEC 104 variantcisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarEN100 Ethernet module Modbus TCP variantcisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarEN100 Ethernet module PROFINET IO variantcisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarOther SIPROTEC 4 relayscisa_csaf_ot
Currently no remediation is available
- Kein Fix verfügbarOther SIPROTEC Compact relayscisa_csaf_ot
Currently no remediation is available
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 3.5–5.3
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (84)
Betroffene Produkte und Versionsbereiche.
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-203306SSA-203306: Password Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Relay Families2018-03-08csaf · siemens_psirtDE
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, and recommends specific countermeasures for the remaining products.
- ICSA-18-067-01Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module (Update D)2018-03-08icsa · cisa_csaf_otUS
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, and recommends specific countermeasures for the remaining products.
auch bekannt als (7)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdfcnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdfPatchVendor Advisorynvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01Third Party AdvisoryUS Government Resourcenvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan