CVE-2018-10612
highPriorität · verfolgen · 39OT-Risiko · erhöhtEPSS 0.013 · 69. PerzentilDEEUUSEPSS · bewertet 2026-10-27
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- Behobenfesto_psirt
For CVE-2010-5250, CVE-2017-3735, CVE-2018-0739, CVE-2018-10612, CVE-2018-20025, CVE-2018-20026, CVE-2019-13532, CVE-2019-13542, CVE-2019-13548, CVE-2019-18858, CVE-2019-9008, CVE-2019-9009, CVE-2019-9010, CVE-2019-9012, CVE-2020-7052: Update to version 2.4.2.0. This also fixes CODESYS Advisory 2017-01, CODESYS Advisory 2017-03, CODESYS Advisory 2017-06, CODESYS Advisory 2017-07, CODESYS Advisory 2017-09, CODESYS Advisory 2018-04, CODESYS Advisory 2018-05, CODESYS Advisory 2018-07, CODESYS Advisory 2018-11.
- Behobentrumpf_psirt
- We highly recommend updating to TruControl version 3.16.0 or higher as soon as possible - Please contact your service partner (service.tls@trumpf.com) for immediate instructions on how to retrieve the update
- MitigationFesto Automation Suite <2.8.0.138 installed with CODESYS Development System 3.0festo_psirt
Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.
- MitigationFesto Automation Suite <2.8.0.138 installed with CODESYS Development System 3.5.16.10festo_psirt
Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.
- MitigationCODESYS Control RTE V3cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control RTE V3 (for Beckhoff CX)cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control V3 Runtime System Toolkitcisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control Win V3 (also part of the CODESYS setup)cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for BeagleBonecisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for IOT2000cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for Linuxcisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for PFC100cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for PFC200cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for Raspberry Picisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS Control for emPC-A/iMX6cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS HMI V3cisa_csaf_ot
Activate and apply user management and password features
- MitigationCODESYS V3 Simulation Runtime (part of the CODESYS Development System)cisa_csaf_ot
Activate and apply user management and password features
- MitigationControl for BeagleBonecisa_csaf_ot
Activate and apply user management and password features
- MitigationFesto Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-D (All versions)cisa_csaf_ot
(CVE-2018-20026, CVE-2019-9010¸ CVE-2010-5250, CVE-2019-9008, CVE-2019-18858, CVE-2019-13548, CVE-2019-13542, CVE-2019-9009, CVE-2019-9012, CVE-2020-7052, CVE-2019-13532, CVE-2018-20025, CVE-2018-10612, CVE-2017-3735) (Product Group: Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-D(All versions), Festo Firmware (R06 (11.10.2016) = 2.3.8.1) installed on Festo Hardware Controller CECC-LK(All versions), Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-S(All versions)): Update to version 2.4.2.0. This also fixes CODESYS Advisory 2017-01, CODESYS Advisory 2017-03, CODESYS Advisory 2017-06, CODESYS Advisory 2017-07, CODESYS Advisory 2017-09, CODESYS Advisory 2018-04, CODESYS Advisory 2018-05, CODESYS Advisory 2018-07, CODESYS Advisory 2018-11.
- MitigationFesto Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-S (All versions)cisa_csaf_ot
(CVE-2018-20026, CVE-2019-9010¸ CVE-2010-5250, CVE-2019-9008, CVE-2019-18858, CVE-2019-13548, CVE-2019-13542, CVE-2019-9009, CVE-2019-9012, CVE-2020-7052, CVE-2019-13532, CVE-2018-20025, CVE-2018-10612, CVE-2017-3735) (Product Group: Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-D(All versions), Festo Firmware (R06 (11.10.2016) = 2.3.8.1) installed on Festo Hardware Controller CECC-LK(All versions), Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-S(All versions)): Update to version 2.4.2.0. This also fixes CODESYS Advisory 2017-01, CODESYS Advisory 2017-03, CODESYS Advisory 2017-06, CODESYS Advisory 2017-07, CODESYS Advisory 2017-09, CODESYS Advisory 2018-04, CODESYS Advisory 2018-05, CODESYS Advisory 2018-07, CODESYS Advisory 2018-11.
- MitigationFesto Firmware (R06 (11.10.2016) = 2.3.8.1) installed on Festo Hardware Controller CECC-LK (All versions)cisa_csaf_ot
(CVE-2018-20026, CVE-2019-9010¸ CVE-2010-5250, CVE-2019-9008, CVE-2019-18858, CVE-2019-13548, CVE-2019-13542, CVE-2019-9009, CVE-2019-9012, CVE-2020-7052, CVE-2019-13532, CVE-2018-20025, CVE-2018-10612, CVE-2017-3735) (Product Group: Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-D(All versions), Festo Firmware (R06 (11.10.2016) = 2.3.8.1) installed on Festo Hardware Controller CECC-LK(All versions), Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-S(All versions)): Update to version 2.4.2.0. This also fixes CODESYS Advisory 2017-01, CODESYS Advisory 2017-03, CODESYS Advisory 2017-06, CODESYS Advisory 2017-07, CODESYS Advisory 2017-09, CODESYS Advisory 2018-04, CODESYS Advisory 2018-05, CODESYS Advisory 2018-07, CODESYS Advisory 2018-11.
- MitigationFesto Firmware (R06 (11.10.2016) = 2.3.8.1) installed on Festo Hardware Controller CECC-S (All versions)cisa_csaf_ot
(CVE-2018-20026, CVE-2019-9010¸ CVE-2010-5250, CVE-2019-9008, CVE-2019-18858, CVE-2019-13548, CVE-2019-13542, CVE-2019-9009, CVE-2019-9012, CVE-2020-7052, CVE-2019-13532, CVE-2018-20025, CVE-2018-10612, CVE-2017-3735) (Product Group: Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-D(All versions), Festo Firmware (R06 (11.10.2016) = 2.3.8.1) installed on Festo Hardware Controller CECC-LK(All versions), Festo Firmware (R05 (17.06.2016) = 2.3.8.0) installed on Festo Hardware Controller CECC-S(All versions)): Update to version 2.4.2.0. This also fixes CODESYS Advisory 2017-01, CODESYS Advisory 2017-03, CODESYS Advisory 2017-06, CODESYS Advisory 2017-07, CODESYS Advisory 2017-09, CODESYS Advisory 2018-04, CODESYS Advisory 2018-05, CODESYS Advisory 2018-07, CODESYS Advisory 2018-11.
- MitigationFesto Automation Suite <2.8.0.138 installed with CODESYS Development System 3.0cisa_csaf_ot
Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.
- MitigationFesto Automation Suite <2.8.0.138 installed with CODESYS Development System 3.5.16.10cisa_csaf_ot
Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 9–10
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (53)
Betroffene Produkte und Versionsbereiche.
- CODESYS Development System 3.5.21.20 external component of Festo Automation Suite 2.8.0.138alle Versionenfixedcisa_csaf_otUScpe:2.3:a:codesys:development_system:3.5.21.20*:*:*:*:*:*:*:*
- Festo Automation Suite <2.8.0.138 installed with CODESYS Development System 3.0alle Versionencisa_csaf_otUScpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*
- Festo Automation Suite <2.8.0.138 installed with CODESYS Development System 3.5.16.10alle Versionencisa_csaf_otUScpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*
- 3S-Smart 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0≤ 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0enisa_euvdEU
- CODESYS Development System 3.5.21.20 external component of Festo Automation Suite 2.8.0.138alle Versionenfixedfesto_psirtDEcpe:2.3:a:codesys:development_system:3.5.21.20*:*:*:*:*:*:*:*
- Festo Automation Suite <2.8.0.138 installed with CODESYS Development System 3.0alle Versionenfesto_psirtDEcpe:2.3:a:codesys:development_system:3.0:*:*:*:*:*:*:*
- Festo Automation Suite <2.8.0.138 installed with CODESYS Development System 3.5.16.10alle Versionenfesto_psirtDEcpe:2.3:a:codesys:development_system:3.5.16.10:*:*:*:*:*:*:*
- codesys control for beaglebone sl3.0 → 3.5.14.0nvdUScpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*
Advisories (6)
Hersteller- und Ökosystem-Meldungen dazu.
- FSA-202202Festo: Controller CECC-S,LK,D family <= 2.3.8.1 - multiple vulnerabilities in CODESYS V3 runtime system2022-07-18csaf · festo_psirtDE
The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.
- FSA-202601Several CODESYS vulnerabilities in Festo Automation Suite2026-02-26csaf · festo_psirtDE
Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently. This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite. Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.
- VDE-2021-033TRUMPF Laser GmbH: multiple products prone to codesys runtime vulnerabilities2021-08-12csaf · trumpf_psirtDE
The TruControl laser control software (versions 1.04 to 3.0.0) uses CODESYS runtime versions affected by multiple CVEs: **CVE list:** - CVE-2021-29242 - CVE-2021-29241 - CVE-2019-5105 - CVE-2020-7052 - CVE-2019-9012 - CVE-2019-9010 - CVE-2019-9009 - CVE-2018-10612 In addition to the CVEs listed above, the affected products are also vulnerable to the following issues without a CVE ID: --- ### **CODESYS Advisory 2018-07** A crafted communication request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition. - **CVSS v3.0 base score:** 6.5 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12928&token=6d1dcea05a15aeef7ad48eadc64c8eca5d4f07b2&download=) --- ### **CODESYS Advisory 2018-04** The CODESYS runtime system allows access to files outside the restricted working directory of the controller by online services. - **CVSS v3.0 base score:** 9.9 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12925&token=50e7240fa947ea215311e3db441f82152f1109b6&download=) --- ### **CODESYS Advisory 2017-03** A crafted request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition. - **CVSS v3.0 base score:** 7.5 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12912&token=2f23e7f047c2768dd06fdf072de49a7ba1fe9687&download=)
- ICSA-18-352-033S-Smart Software Solutions GmbH CODESYS Control V3 Products2018-12-18icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could allow unauthorized access and exfiltration of sensitive data including user credentials.
- ICSA-25-273-04Festo Controller CECC-S,-LK,-D Family Firmware (Update A)2025-09-30icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to crash services, escalate privileges, bypass authentication, or gain unauthorized access to sensitive systems and data.
- ICSA-26-076-01CODESYS in Festo Automation Suite2026-02-26icsa · cisa_csaf_otUS
Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently. This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite. Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (8)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.securityfocus.com/bid/106248cnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-352-03cnnvd
- https://www.codesys.com/Patchcnnvd
- https://www.securityfocus.com/bid/106248cnnvd
- http://www.securityfocus.com/bid/106248enisa_euvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-352-03enisa_euvd
- http://www.securityfocus.com/bid/106248Third Party AdvisoryVDB Entrynvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-352-03Third Party AdvisoryUS Government Resourcenvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.