CVE-2018-0324

mediumPriorität · verfolgen · 27EPSS 0.007 · 51. PerzentilEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.66% (51st) EPSS
CVSS 4.6 · medium
Is it mine?
5 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · cisco_csaf · nvd

EPSS · bewertet 2026-10-27

A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.7
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.04.6mediumAV:L/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 6.4
v3.16.7mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 0.8 · Auswirkung 5.9
v3.04.2mediumCVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:Lsecondary · Cisco PSIRT US
v3.16.1mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (5)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • cisco-sa-20180516-nfvis-cli-command-injectionCisco Enterprise NFV Infrastructure Software CLI Command Injection Vulnerability2018-05-16csaf · cisco_csafUS

    A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. There are no workarounds that address this vulnerability. This advisory is available at the following link: https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection ["https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection"]

07

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2018-05-17geändert 2026-06-17
10

Referenzen (6)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan